    Default I use the fireplace all the time, there is nothing wrong with it

    Sometimes you can only shake your head and walk away...

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Last edited by Alton Darty; 04-12-2016 at 04:03 PM. Reason: wrong photo posted
    Inspection Referral
    Alton Darty
    ATN Services, LLC
    www.arinspections.com

  2. #2
    Join Date
    Oct 2010
    Location
    MONTREAL QUEBEC-CANADA
    Posts
    2,075

    Default Re: I use the fireplace all the time, there is nothing wrong with it

    I will post a shot of last weeks. fire box when I get back in the office. Built in fire suppression.

    Robert Young's Montreal Home Inspection Services Inc.
    Call (514) 489-1887 or (514) 441-3732
    Our Motto; Putting information where you need it most, "In your hands.”

  3. #3
    Join Date
    Oct 2010
    Location
    MONTREAL QUEBEC-CANADA
    Posts
    2,075

    Default Re: I use the fireplace all the time, there is nothing wrong with it

    There was bulk water stream down the fire box walls.
    fire box.jpg
    Maybe it was installed in a unit with a sub panel.

    Robert Young's Montreal Home Inspection Services Inc.
    Call (514) 489-1887 or (514) 441-3732
    Our Motto; Putting information where you need it most, "In your hands.”

  4. #4
    Join Date
    Mar 2007
    Location
    Near Philly, Pa.
    Posts
    1,682

    Default Re: I use the fireplace all the time, there is nothing wrong with it

    Looks like someone removed the damper and a few firebricks to get a chimney liner down for a wood insert stove that was later removed but the fireplace was never repaired. Some firebricks, parge with Chamber Tech 2000 and a top mounted damper and Bob's your uncle unless there are other issues with it. About a $1,500-2K repair depending upon local market conditions. Look on the bright side: without a pesky throat damper someone can stand up and hand parge the smoke chamber right up to the first flue tile making a smooth transition that reduces the chance of smoke spillage while improving the chamber's dire durability. Level II inspection triggered.

    Keep the fire in the fireplace.