    Default Metal Chimney distance from an operable window and above soffit

    Need clearances for this chimney exhaust from an operable window and above soffit. Picture attached

    Thanks, Jim

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Inspection Referral SOC

  2. #2
    Join Date
    Jul 2008
    Location
    Chicago
    Posts
    263

    Default Re: Metal Chimney distance from an operable window and above soffit

    8' clearance from vertical walls so that doesn't cut it. It's more accurately a B-vent and not a chimney.

    Mike Lamb
    Inspection Connection, Inc.
    http://www.inspection2020.com/

  3. #3
    Join Date
    Mar 2007
    Location
    Ormond Beach, Florida
    Posts
    26,406

    Default Re: Metal Chimney distance from an operable window and above soffit

    It's 8' from the sidewall, minimum, or 2' above the roof above.

    It's also, as I recall, 10' from a building opening (windows, doors, soffit vents, etc.

    Jerry Peck, Construction / Litigation Consultant
    Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
    www.AskCodeMan.com