Results 1 to 3 of 3
  1. #1
    Join Date
    Apr 2007
    Location
    WESTMINSTER CO
    Posts
    1,154

    Default Multiple string of fireplace gas lines

    Hi Guys<br>
    <br>
    Long time since i've posted -but i read alot here. Came across this today 2015 house -three 4 foot plus or minus flex gas lines running from basement to gas fireplace in family room--not csst just flex lines--this is a big major No No right. Buyer bought house five years ago and no write up on this.<br>
    <br>
    thanks<br>
    <br>
    charlie

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Last edited by CHARLIE VAN FLEET; 11-02-2024 at 12:08 PM. Reason: no photo
    Member Benefits1

  2. #2
    Join Date
    Apr 2007
    Location
    WESTMINSTER CO
    Posts
    1,154

    Default Re: Multiple string of fireplace gas lines

    Guys

    found out it was to the new gas stove recently installed--but think same no no

    cvf


  3. #3
    Join Date
    Mar 2007
    Location
    Orlando, FL
    Posts
    1,594

    Default Re: Multiple string of fireplace gas lines

    Charlie,

    I just saw your post, sorry it's probably a few days too late, but here's some relevant data for gas connectors:

    411.1.3.1 Maximum length.

    Connectors shall have an overall length not to exceed 6 feet (1829 mm). Measurement shall be made along the centerline of the connector. Only one connector shall be used for each appliance.