Multiple string of fireplace gas lines
Hi Guys<br>
<br>
Long time since i've posted -but i read alot here. Came across this today 2015 house -three 4 foot plus or minus flex gas lines running from basement to gas fireplace in family room--not csst just flex lines--this is a big major No No right. Buyer bought house five years ago and no write up on this.<br>
<br>
thanks<br>
<br>
charlie
Similar Threads:Last edited by CHARLIE VAN FLEET; 11-02-2024 at 12:08 PM. Reason: no photo
-
11-02-2024, 01:24 PM #2
Re: Multiple string of fireplace gas lines
Guys
found out it was to the new gas stove recently installed--but think same no no
cvf
-
11-09-2024, 05:29 AM #3
Re: Multiple string of fireplace gas lines
Charlie,
I just saw your post, sorry it's probably a few days too late, but here's some relevant data for gas connectors:
411.1.3.1 Maximum length.
Connectors shall have an overall length not to exceed 6 feet (1829 mm). Measurement shall be made along the centerline of the connector. Only one connector shall be used for each appliance.