Results 1 to 3 of 3
  1. #1
    Join Date
    Mar 2007
    Location
    Oklahoma City
    Posts
    357

    Default Is this a vent-free

    This gas log set was too bg for the fireplace causing the front burner to cook the paint off the front of the draft hood. There were no tags or manuals, so I was wondering if someone can tell if this is a vent-free by looking at the burner?

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Member Benefits1
    If it weren't for lawyers, we would never need them.

  2. #2
    Join Date
    Mar 2007
    Location
    Near Philly, Pa.
    Posts
    1,682

    Cool Re: Is this a vent-free

    Yep, that's an ODS pilot. If there is no rating plate, it should be removed. Even if it is VF, you need to ascertain if that fireplace allows VF logs. If that fireplace is not listed for use with VF, it should be removed for a Level III inspection.

    Get a pro in there.
    Bob

    Keep the fire in the fireplace.

  3. #3
    Join Date
    Mar 2007
    Location
    Oklahoma City
    Posts
    357

    Default Re: Is this a vent-free

    Thanks Bob, that confirms what I was thinking. I was hoping to catch you as I am working late on reports.

    If it weren't for lawyers, we would never need them.