    Default flue clearance and installation

    see any problem with the flue height etc on this roof.

    Noted this Bvent should be 1" to combustables as well right?

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Crawl Space Creeper

  2. #2
    Join Date
    Aug 2007
    Location
    Memphis TN.
    Posts
    4,311

    Default Re: flue clearance and installation

    Quote Originally Posted by Jerome W. Young View Post
    see any problem with the flue height etc on this roof.
    Other than it's not at least 2 ft higher than any portion of the building within 10 feet ?

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
    Billy J. Stephens HI Service Memphis TN.

  3. #3
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: flue clearance and installation

    Quote Originally Posted by Billy Stephens View Post
    Other than it's not at least 2 ft higher than any portion of the building within 10 feet ?

    Not counting the sloped roof, but referring to the wall nearby, right?

    Each slope roof has a minimum height above it, I believe it starts at 1 foot.

    Now, if that wall is within 8 feet, the gas vent needs to be 2 feet higher than the wall/roof at the wall.

    Of course, they are also supposed to be vertical too (just not sure how far off vertical is allowed where it comes out above the roof).

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  4. #4
    Join Date
    Aug 2007
    Location
    Memphis TN.
    Posts
    4,311

    Default Re: flue clearance and installation

    Quote Originally Posted by Billy Stephens View Post
    Other than it's not at least 2 ft higher than any portion of the building within 10 feet ?
    Quote Originally Posted by Jerry Peck View Post
    -- referring to the wall nearby, right?
    Oops,

    Single wall vent Reference IRC 2006 2427.7.3 = 10 feet

    It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)