You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 02-24-2008, 10:28 AM
Bart Ogden Bart Ogden is offline
Member
 
Join Date: Oct 2007
Location: Wichita, KS
Posts: 15
Superior CF4360 Gap at Smoke Chamber/Piping Transition
Gentlemen:

I'm looking for any information on a Superior CF4360 FP#Y-73057 regarding a visible gap at the smoke chamber/flue transition.
Anyone else ever see one of these that really looks like the gap belongs there?

In almost thirty years of hearth servicing, we've never come across this particular model.

Sincerely,
A. Bart Ogden, President
Home Safe Hearth & Chimney, Inc.
Wichita, KS
Voice 316-265-9828
Fax 316-265-9890
www.HomeSafeKS.com
Reply With Quote
  #2 (permalink)  
Old 02-24-2008, 11:38 AM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,751
Re: Superior CF4360 Gap at Smoke Chamber/Piping Transition
Quote:
Originally Posted by Bart Ogden View Post
Gentlemen:

I'm looking for any information on a Superior CF4360 FP#Y-73057 regarding a visible gap at the smoke chamber/flue transition.
Anyone else ever see one of these that really looks like the gap belongs there?

In almost thirty years of hearth servicing, we've never come across this particular model.

Sincerely,
A. Bart Ogden, President
Home Safe Hearth & Chimney, Inc.
Wichita, KS
Voice 316-265-9828
Fax 316-265-9890
www.HomeSafeKS.com
I'm guessing that this is a fireplace made by Superior? For the most, we are only humble home inspectors and we need a little more information at times..

If you have a picture it would be very helpful, but I wouldn't think that you would want to see any gaps.
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #3 (permalink)  
Old 02-24-2008, 12:13 PM
Bart Ogden Bart Ogden is offline
Member
 
Join Date: Oct 2007
Location: Wichita, KS
Posts: 15
Re: Superior CF4360 Gap at Smoke Chamber/Piping Transition
Hi Scott,

I'm looking for chimney inspectors' feedback on this particular issue. I realize that home inspectors wouldn't have information on this.

Bart
Reply With Quote
  #4 (permalink)  
Old 02-24-2008, 03:52 PM
Bob Harper's Avatar
Bob Harper Bob Harper is offline
Member
 
Join Date: Mar 2007
Location: Pa.
Posts: 577
Re: Superior CF4360 Gap at Smoke Chamber/Piping Transition
Hi Bart, how have you been?

I am not intimately familiar with this model Superior box so I cannot help you on it. I do know there is an intentional gap on all Heatilators and most Heat&Glos for the last 15 yrs. This is where the cooling air from the bottom and side louvers dumps into the flue to:
a) cool the firebox
b) turbo charge the flue gases.

The old Heatilator Mark 123 did this using louvers at the top of the smoke chamber.

If Lennox (Superior) Tech Support cannot help, try Jimmy Kress at Specialty Supply in Cherry Hill, NJ. He sells replacement parts to sweeps for older Superior and Marco units and advertising in Alt. Energy Retailer Mag. 800-331-9234

HTH,
Bob Harper
__________________
disgusted with some people on this forum. Out of here!
Reply With Quote
Are inspection referrals from past clients important to you? If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
flat to pitch transition Jerome W. Young Roofing System: Home Inspection and Commercial Inspection 15 02-26-2008 01:49 PM
Debris in combustion chamber JD Johnson Plumbing System: Home Inspection and Commercial Inspection 8 02-03-2008 03:22 PM
CTSX Piping Jerome W. Young Plumbing System: Home Inspection and Commercial Inspection 9 12-28-2007 11:32 AM
galvanized piping Scott Lynch Plumbing System: Home Inspection and Commercial Inspection 5 07-22-2007 07:36 PM
Unknown piping. Eric Shuman Plumbing System: Home Inspection and Commercial Inspection 11 05-14-2007 08:09 PM


All times are GMT -7. The time now is 12:06 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger