You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 01-01-2008, 11:21 AM
dan orourke dan orourke is offline
Member
 
Join Date: Mar 2007
Location: dust in the wind
Posts: 157
Sheer wall
.........

Last edited by dan orourke : 01-02-2008 at 08:34 AM.
Reply With Quote
Home inspection
  #2 (permalink)  
Old 01-01-2008, 11:55 AM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 672
Re: Sheer wall
It is a shear wall (not sheer).

A shear wall is a structural wall designed to resist lateral loads along the wall. These loads are typically wind or earthquake loads. Shear walls may or may not be load-bearing.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #3 (permalink)  
Old 01-01-2008, 12:28 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
Re: Sheer wall
Here is a non-technical example.

Take a 30 foot by 50 foot building, no interior walls. The wind blows against the 50 foot walls and blows it in.

Now, build a shear wall perpendicular to, and against, the center of that 50 foot wall, effectively creating two 25 foot walls with a 'T' wall in the center. The same wind blows against that 50 foot wall and the shear wall in the center holds the wall up.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
  #4 (permalink)  
Old 01-02-2008, 07:41 AM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,073
Re: Sheer wall
See the first four diagrams here:

YOSHINO GYPSUM CO., LTD. | About "Gypsum"/What's "Shear Wall"?

It's "shear" wall, BTW, a "sheer" wall is one is vertical or nearly so.
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #5 (permalink)  
Old 01-02-2008, 05:53 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
Re: Sheer wall
Try this: (click on the bulleted numbers 1, 2, 3, 4)

Loadpath Demo
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
  #6 (permalink)  
Old 01-06-2008, 09:56 AM
Eric Shuman Eric Shuman is offline
Member
 
Join Date: Mar 2007
Location: Austin, TX
Posts: 262
Re: Sheer wall
Why are all of Dan's posts edited so that we can not see the original question? Am I missing something here?


Eric
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
SIngle wall? Clay E White Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 2 07-26-2007 06:34 PM
SIngle wall? Jeff Eastman Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 1 07-02-2007 11:04 PM
Wall plumb John Stephenson Building Interior: Home Inspection and Commercial Inspection 2 06-03-2007 12:34 PM
Wall temperature Vince Santos Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 23 05-11-2007 01:07 PM
Crack in the wall Mike Huppi Building Interior: Home Inspection and Commercial Inspection 17 04-18-2007 11:44 AM


All times are GMT -7. The time now is 12:06 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger