InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 12-11-2008, 05:09 PM
tim reaves tim reaves is offline
Member
 
Join Date: Mar 2007
Posts: 2
foundation this can be correct
In the photo you can see the foundation thin the bottom plate and then a piece of plywood shimming up the outside band Joist. could this type of shimming have been approved.
Attached Images
File Type: jpg IMG_4031.jpg (51.2 KB, 113 views)
File Type: jpg IMG_4032.jpg (58.3 KB, 92 views)
Reply With Quote
IC Home Inspection Report Writing
  #2 (permalink)  
Old 12-11-2008, 05:14 PM
Richard Pultar Richard Pultar is offline
Member
 
Join Date: Oct 2008
Location: new jersey
Posts: 181
Re: foundation this can be correct
ask who ever approved it
Reply With Quote
  #3 (permalink)  
Old 12-11-2008, 06:19 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,293
Re: foundation this can be correct
Tim,

No, plus, with that anchor bolt shown holding that sill down, I suspect there should be some uplift straps too.

It does not good to hold the sill plate down and not strap the stuff above it to the sill plate.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #4 (permalink)  
Old 12-12-2008, 05:06 AM
A.D. Miller's Avatar
A.D. Miller A.D. Miller is offline
Member
 
Join Date: Sep 2008
Location: In A Tempranillo Haze
Posts: 2,725
Re: foundation this can be correct
Quote:
Originally Posted by tim reaves View Post
In the photo you can see the foundation thin the bottom plate and then a piece of plywood shimming up the outside band Joist. could this type of shimming have been approved.
No.

Plus:

(1) Softwood shims on th top of the pier are wrong.
(2) Girder (beam) is not properly built.
(3) Insulation batts are backwards with the vapror retarder facing the crawl space.

Aaron
Reply With Quote
  #5 (permalink)  
Old 12-12-2008, 05:07 AM
A.D. Miller's Avatar
A.D. Miller A.D. Miller is offline
Member
 
Join Date: Sep 2008
Location: In A Tempranillo Haze
Posts: 2,725
Re: foundation this can be correct
Quote:
Originally Posted by tim reaves View Post
In the photo you can see the foundation thin the bottom plate and then a piece of plywood shimming up the outside band Joist. could this type of shimming have been approved.
Sorry I forgot:

(4) Girder (beam) not centered on top of pier.

Aaron
Reply With Quote
  #6 (permalink)  
Old 12-12-2008, 10:35 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,293
Re: foundation this can be correct
Aaron,

If you are going to get into everything you see, those "soft wood shims" you see is a piece of plywood, and plywood is does not make a suitable shim.

It is much easier to make a list of what one sees correct in that photo, such as:

1)






(well, I tried to find something correct)
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #7 (permalink)  
Old 12-12-2008, 10:52 AM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,655
Re: foundation this can be correct
Noticed that there is no termite shield installed on the pier either.

Aaron,
That infamous SE here in Dallas that we all have come to know over the years says that the girder beam does not have to be exactly centered over the pier as long as 60% of the beam is on top of the pier. Have you heard this?

rick
Reply With Quote
  #8 (permalink)  
Old 12-12-2008, 11:56 AM
tim reaves tim reaves is offline
Member
 
Join Date: Mar 2007
Posts: 2
Re: foundation this can not be correct
the whole foundation needs to be reviewed by a engineer. how about the bottom of the trusts not sitting on top of the top plate.
Attached Images
File Type: jpg 9240 (1).jpg (23.9 KB, 45 views)
File Type: jpg 9480 (1).jpg (26.7 KB, 47 views)
File Type: jpg 9400.10 (1).jpg (27.6 KB, 41 views)
Reply With Quote
  #9 (permalink)  
Old 12-12-2008, 12:31 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,655
Re: foundation this can be correct
Tim,

I agree with you. The more pics you post, the worse it gets.

The only difference is I see no need to recommend a "review" by a Structural Engineer. I just state that the foundation needs to be repaired by a Reputable foundation company familar with Pier and Beam foundations and note what I've seen.

Why have the client spend the 300+ dollars on a SE to tell them it needs repairs which you have already told them.

JMHO

Rick
Reply With Quote
FREA Home Inspector Insurance
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Foundation crack below beam near foundation corner Michael Thomas Structural Components: Home Inspection and Commercial Inspection 70 02-12-2009 02:19 AM
Is flashing correct at chimney? Leon Mann Roofing System: Home Inspection and Commercial Inspection 31 12-11-2008 08:33 PM
Is this ground correct? Marc M Electrical Systems: Home Inspection and Commercial Inspection 9 11-28-2008 06:32 AM
Correct construction???? JIM MURPHY Building Interior: Home Inspection and Commercial Inspection 7 08-07-2008 02:35 PM
Commercial Foundation vs Residential Foundation Wendell Swedberg Structural Components: Home Inspection and Commercial Inspection 2 07-12-2008 07:53 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 04:04 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger