You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 02-24-2008, 07:32 PM
Don Sweet Don Sweet is offline
Member
 
Join Date: Dec 2007
Location: Garden Ridge, Texas
Posts: 12
Building Inspector - first post
Do you require an emergency egress opening in a second floor MEDIA or BONUS room in a new residence when the room is NOT marked bedroom on the plans? IRC says no...my partner says, "yes."
Reply With Quote
  #2 (permalink)  
Old 02-24-2008, 07:49 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
Re: Building Inspector - first post
Quote:
Originally Posted by Don Sweet View Post
when the room is NOT marked bedroom on the plans? IRC says no...my partner says, "yes."
Does not matter what it is "marked" on the plans ... *is* it a bedroom?

I.e., does it have a smoke detector as required for bedrooms.

Does it have natural light and ventilation?

Does it have a closet?

If it is a "bedroom" in all but name, then yes, it should have an EERO.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
  #3 (permalink)  
Old 02-25-2008, 07:01 AM
Don Sweet Don Sweet is offline
Member
 
Join Date: Dec 2007
Location: Garden Ridge, Texas
Posts: 12
Re: Building Inspector - first post
Hi Jerry,

Thanks for your reply. In the discussion I had with IRC, I was told that a person could sleep in any room. An upstairs MEDIA room with a smoke detector, bathroom for convenience, and closet for storage of media equipment would NOT require an EE exit...albeit probably a good idea. If an EE would be required because the room had a closet, natural light and a smoke detector, the Code would probably require an EE in ALL second floor rooms...

Don
Reply With Quote
  #4 (permalink)  
Old 02-25-2008, 07:25 AM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
Re: Building Inspector - first post
Don,

If it looks like a duck, walks like a duck, and quacks like a duck ... it's duck ... regardless of what the IRC says about it.

What happens when the next owner uses that for what it is ... a bedroom ... and someone dies in there? *I* would not want to get that phone call.

"In the discussion I had with IRC, I was told that a person could sleep in any room."

Yes, you can even sleep in the kitchen, but that does not make it a "bedroom" - heck, you can even sleep in the attic or garage, but that does not make them "bedrooms".

The critical factors should be: a) does it have a smoke detector; b) does it have a closet suitable for clothes - not just a small storage closet for the equipment; c) does it have a window for natural light and ventilation?

Many media rooms I've seen have been able to get by without the required "natural light and ventilation" because ... the window would be kept closed and the black out shades kept drawn. I don't necessarily agree with those allowances, but, if the AHJ allows them, then that room does not meet the requirements of a "bedroom". Put in a window and that room does become "a bedroom" and that window should meet the EERO requirements.

"Bedrooms" are not 'rooms where one can sleep', they are intended for use as 'sleeping rooms', and, if the room meets the requirements of a 'sleeping room' and can be used for that purpose, then it "likely will become a sleeping room (i.e., "bedroom) at some point in time".

I know the ICC people are making 'allowances' for new rooms, but to me (old fashioned me) thinks "If it looks like a duck, walks like a duck, and quacks like a duck ... it's duck.", I don't care if the builder does call it a "dog" room on the plans ... when the Aflack duck waddles in and makes it it's room, it's a "duck" room.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )

Last edited by Jerry Peck : 02-25-2008 at 09:02 AM. Reason: a duck "quacks" not "quakes" ... unless a bigger animal is chasing it - Thanks Jim.
Reply With Quote
  #5 (permalink)  
Old 02-25-2008, 07:55 AM
Jim Luttrall Jim Luttrall is offline
Member
 
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,449
Re: Building Inspector - first post
Quote:
and quakes like a duck ... it's duck.",
Is that one of those ducks from high seismic areas?

I see these media rooms and game rooms in new construction in several different jurisdictions and it is always readily apparent the intent of the room. Media rooms having no windows, closet or smoke detectors. Of course there are always 3 or more bedrooms that do meet all the qualifications.

I DO make mention that the non-conforming rooms should not be converted to bedrooms since it would be a "Fry room" (Jerry P.'s term) instead of a bedroom.
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
Reply With Quote
  #6 (permalink)  
Old 02-25-2008, 08:55 AM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is online now
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,135
Re: Building Inspector - first post
We have a room as such at our home and it has no windows. Home is approx. 2 years old. It is on the second floor and has (3) other bedroom locations on that floor.

There is a smoke detector inside the room and opposite the door to the room.

A true theatre room is not going to have a window it in it as the daylight obstructs the screen.

In the homes in the Dallas area that I personally inspect, I'm not seeing windows in the theatre rooms. They are not bedrooms.

rick
Reply With Quote
  #7 (permalink)  
Old 02-25-2008, 09:02 AM
Michael Larson's Avatar
Michael Larson Michael Larson is offline
Member
 
Join Date: Mar 2007
Location: Hudson, WI
Posts: 365
Re: Building Inspector - first post
Quote:
Originally Posted by Rick Hurst View Post
In the homes in the Dallas area that I personally inspect, I'm not seeing windows in the theatre rooms. They are not bedrooms.

rick
In the land of basements I have been seeing a lot of theater rooms on the lowest level, some under the garage. One entrance, no windows, etc.

They are not considered bedrooms in my area.
Reply With Quote
  #8 (permalink)  
Old 02-25-2008, 09:07 AM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,644
Re: Building Inspector - first post
Quote:
Originally Posted by Rick Hurst View Post
In the homes in the Dallas area that I personally inspect, I'm not seeing windows in the theatre rooms. They are not bedrooms.

While they are not "bedrooms" they are "habitable spaces" and "habitable spaces" are required to have natural light and ventilation. Therein lies the problem. Put in windows to meet that requirement and you might push the room into the realm of being a bedroom. Do not put windows in and you are violating the code - even if the AHJ says it is okay to not put windows in - it is specifically against the IRC and the AHJ is not allowed to 'interpret' against the specifically written IRC ... says so in the IRC itself.

That said, I go for no windows in that room, to reduce the likelihood that it will someday become a bedroom, meaning 'it no longer looks like a duck', therefore it might not be a duck.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
New post- old Inspector Jerry Weaver Introductions By New Members 0 02-16-2008 09:53 AM
Green/Eco Building Joe Nernberg Building Envelope: Home Inspection and Commercial Inspection 8 09-10-2007 08:12 PM
Small-business owners warned not to risk ruin building a company - Seattle Post Intel Brian Hannigan Business Operations: Home Inspectors & Commercial Inspectors 0 08-12-2007 07:30 AM
Post your Illinois Inspector related stuff here Joe Tribuzio General Chit Chat: Home Inspectors & Commercial Inspectors 1 06-02-2007 08:17 AM
REAL ESTATE MAILBAG Is There Recourse With an Inspector Mishap? - Washington Post Brian Hannigan Inspection News From Around The Net 0 03-23-2007 02:40 PM


All times are GMT -7. The time now is 11:25 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger