Results 1 to 4 of 4
  1. #1
    Stephen G Sheldon's Avatar
    Stephen G Sheldon Guest

    Default Flue Attachment Mystery

    Saw the attached looking arrangement on a basement forced air furnace being vented to the side of the house. What are these components in the picture?

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Member Benefits1

  2. #2
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: Flue Attachment Mystery

    Its a power vent. Most likely used on high efficiency oil fired furnace or where their is no vertical chimney or where the horizontal flue is too long or slope cannot be adequately provided. Don't see many of them up here but have seen them.

    There is a pressure switch (round disc) which will shut down the furnace if positive pressure on the vent is inadequate.


  3. #3
    Stephen G Sheldon's Avatar
    Stephen G Sheldon Guest

    Default Re: Flue Attachment Mystery

    Raymond, Thanks for your help


  4. #4
    Join Date
    May 2007
    Location
    Frankfort, KY
    Posts
    326

    Default Re: Flue Attachment Mystery

    Was that attached to a furnace that had an open drafthood Stephen?

    If so you might want to call it out as having the potential to be unsafe.