  1. #1
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default HVAC System

    Do you report when you see uninsulated ducts in areas with no heat.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Member Benefits1

  2. #2
    Join Date
    May 2008
    Location
    Atlanta
    Posts
    120

    Default Re: HVAC System

    Are these type of ducts allowed anywhere in HVAC, regardless of heated or not heated area?


  3. #3
    Join Date
    Mar 2007
    Location
    Baton Rouge, La.
    Posts
    91

    Default Re: HVAC System

    That looks like insulated flex duct! Not sure of your question!

    James Bohac

  4. #4
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: HVAC System

    It's flex duct but there is no insulation.


  5. #5
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: HVAC System

    Quote Originally Posted by Brent Crouse View Post
    Are these type of ducts allowed anywhere in HVAC, regardless of heated or not heated area?
    Without being there to verify there was no insulation ... those look like "air connectors" and not "air ducts", and "air connectors" have a VERY LIMITED use and a VERY LIMITED length.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  6. #6
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: HVAC System

    Jerry, there is no insulation. They are very thin. The runs seem pretty short, limited to the closet space.


  7. #7
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: HVAC System

    For one thing, they are not supported properly, as to whether they are even allowed to be used there is another concern - would need to have more information, such as the UL number on them, the manufacturer, etc., as they may (or may not) even be allowed to be used in that installation.

    If that closet is not within the thermal envelope, then the answer is not allowed, if that closet is withing the thermal envelope ... maybe ... is the best I can do right now - but you can write them up for not being properly installed, and from there have a properly licensed and competent mechanical contractor determine if those uninsulated air connectors are even allowed.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  8. #8
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: HVAC System

    Well the thermal envelope is a tricky question. It is a utility closet within the garage and the walls may or may not be insulated. They likely are insulated because there is a bedroom and bathroom above the area. I will get more info off the duct when I return to grab a radon test. Thanks for the help. The installation looked like a bit of hack job to me, but what do I know


  9. #9
    David Bell's Avatar
    David Bell Guest

    Default Re: HVAC System

    Looks like the homeowner wanted some extra returns in the house. Complete hack job.


  10. #10
    Join Date
    Feb 2008
    Location
    Chicago IL
    Posts
    2,048

    Default Re: HVAC System

    Those look like dryer slinkies, not real HVAC flex duct. I don't think it is insulated. Lack of support and poor install are easy write-ups. I'd add verify proper CFM to rooms by HVAC contractor. Those look like maybe 4", which isn't going to sufficiently supply anything beyond a bathroom. Don't see a bypass on that HUM either.

    www.aic-chicago.com
    773/844-4AIC
    "The Code is not a ceiling to reach but a floor to work up from"

  11. #11
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: HVAC System

    Quote Originally Posted by Markus Keller View Post
    Those look like dryer slinkies,

    To me, they look like they are larger than 4", but nonetheless ...

    ... "dryer slinkies" are not even allowed to be used for dryers.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  12. #12
    Join Date
    Mar 2007
    Location
    Near Philly, Pa.
    Posts
    1,682

    Cool Re: HVAC System

    Well, JP you ought to clarify you are allowed to use flexible 'transition ducts' on dryer vents if using the prescribed materials under the prescribed conditions but............

    Somebody tell me how you use a flexible transition duct and maintain a male-up pipe orientation? I've never seen a flex hose that was sized to slip inside a rigid pipe that didn't downsize the duct.

    Keep the fire in the fireplace.

  13. #13
    Join Date
    Mar 2007
    Location
    Spring Hill (Nashville), TN
    Posts
    5,851

    Default Re: HVAC System

    Quote Originally Posted by Bob Harper View Post
    Well, JP you ought to clarify you are allowed to use flexible 'transition ducts' on dryer vents if using the prescribed materials under the prescribed conditions but............

    Somebody tell me how you use a flexible transition duct and maintain a male-up pipe orientation? I've never seen a flex hose that was sized to slip inside a rigid pipe that didn't downsize the duct.
    Those little blue pills might help with rigidity...

    Scott Patterson, ACI
    Spring Hill, TN
    www.traceinspections.com

  14. #14
    Join Date
    Nov 2009
    Location
    St Paul, MN
    Posts
    1,630

    Default Re: HVAC System

    Are you sure those are heat ducts and not return air ducts?

    MinnesotaHomeInspectors.com
    Minnesota Home Inspectors LLC
    ASHI #242887 mnradontesting.com

  15. #15
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: HVAC System

    A contractor evaluated it and said it was fine, just cheap. I asked him about the duct sized and lack of insulation and he could have cared less. Then the buyer was there and asked how much to improve it and he said 1000 to 1500. Glad I said something about it, I don't want to pay for it


  16. #16
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,032

    Default Re: HVAC System

    Quote Originally Posted by Bob Harper View Post
    Well, JP you ought to clarify you are allowed to use flexible 'transition ducts' on dryer vents if using the prescribed materials under the prescribed conditions but............

    Bob,

    Except those slinkies *are not* approved for use as transition duct (dryer connectors) - neither the foil types nor the plastic ones, ONLY the flexible metal ones.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  17. #17
    ray jackson's Avatar
    ray jackson Guest

    Default Re: HVAC System

    What state is that in? In CA code is a minimum R-4.2. As far as that furnace being in the envelope, it doesn't appear to be. I'm not sure what contractor would say that was O.K. If you measured the external static pressure (ESP) I'm sure it would be far outside the capability of the blower. Just a drastic loss in capacity for the system, but hey, if the home owner wants to run a 5 ton A/C to get 4 tons of cooling, good for him.


  18. #18
    Join Date
    Jul 2008
    Location
    Utah
    Posts
    390

    Default Re: HVAC System

    If the installation is in an unheated space you better check the water piping and water softener too.


  19. #19
    Mark Aakjar's Avatar
    Mark Aakjar Guest

    Default Re: HVAC System

    There is also a loss in thermal efficiency here. In New Jersey all branch ducts in new construction must be minimum of R-6