    Cool Clothes Dryer Outlet/Sock

    I haven't seen one of these in three years. I don't understand what makes people think this is acceptable.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Inspection Referral

  2. #2
    Join Date
    Mar 2007
    Location
    Healdsburg, CA
    Posts
    1,741

    Default Re: Clothes Dryer Outlet/Sock

    Joe, the same folks who do this!

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Jerry McCarthy
    Building Code/ Construction Consultant

  3. #3
    Join Date
    Oct 2003
    Location
    Rockwall Texas
    Posts
    4,521

    Default Re: Clothes Dryer Outlet/Sock

    Joe,

    Did that room smell a bit like tuna when the dryer was running?

    That lint can sure have a funny smell to it.

    rick


  4. #4
    Join Date
    Mar 2007
    Location
    Oklahoma City
    Posts
    357

    Default Re: Clothes Dryer Outlet/Sock

    I saw one a little while ago that was at least 20ft long stright up and out the roof with no booster. My question is how long can a dryer vent be before it needs a booster? This one was perfectly vertical and as I said, at least 20ft long. A quick response would be nice as I am writing the report right now. It does not look right to me, but I do not know the specs.

    If it weren't for lawyers, we would never need them.

  5. #5
    Richard Stanley's Avatar
    Richard Stanley Guest

    Default Re: Clothes Dryer Outlet/Sock

    Dryer exhaust
    Max 25' - 5' for 90s, - 2.5 ft for 45s. Smooth metal pipe, no screws. Transition connector max 6'.

    I don't think there is a maximum size for panty hose!!

    Last edited by Richard Stanley; 10-17-2007 at 03:10 PM. Reason: add

  6. #6
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Clothes Dryer Outlet/Sock

    Quote Originally Posted by Richard Stanley View Post
    Dryer exhaust
    Max 25' - 5' for 90s, - 2.5 ft for 45s. Smooth metal pipe, no screws.
    That's everyone's first response, but it is not quite right.

    The answer is what Richard stated with the following added 'or as along as the dryer manufacturer says it can be'. I've seen dryers rated to push 90 feet.

    Just saying 25 feet minus blah-blah is just not correct, it is simply the shortest longest it can be, but it can be longer longest.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired