Results 1 to 17 of 17
  1. #1
    Join Date
    Oct 2010
    Location
    MONTREAL QUEBEC-CANADA
    Posts
    2,075

    Default oil furnace in the garage.

    Exposed oil furnace with AC in the garage.
    Require a narrative considering venting is exposed.
    Looking for a canadian standard or something applicable.

    Similar Threads:
    Inspection Referral
    Robert Young's Montreal Home Inspection Services Inc.
    Call (514) 489-1887 or (514) 441-3732
    Our Motto; Putting information where you need it most, "In your hands.”

  2. #2
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    Picture?
    Is the oil tank in proximity to furnace or on the exterior of garage?
    Is the furnace protected from damage - bollards?
    Not sure what you mean by venting exposed?

    Last edited by Raymond Wand; 12-24-2016 at 04:17 AM.

  3. #3
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    Also found this on oil tanks, although it has nothing to do with your question, its very good information albeit for North West Territories.

    http://www.enr.gov.nt.ca/sites/defau..._oil_tanks.pdf


  4. #4
    Join Date
    Oct 2010
    Location
    MONTREAL QUEBEC-CANADA
    Posts
    2,075

    Default Re: oil furnace in the garage.

    Interior garage.
    Could not locate oil tank.
    Too much stuff.
    Could not get an image with the car removed.
    Plenum, return and supply and branches in the garage.
    Circa 1987 everything.
    furnace.jpg



    Peculiar inspection.
    We all get old. Be grateful you have a child caring for you.

    Robert Young's Montreal Home Inspection Services Inc.
    Call (514) 489-1887 or (514) 441-3732
    Our Motto; Putting information where you need it most, "In your hands.”

  5. #5
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    If it supplies interior of home it's wrong because CO can be carried into living space.


  6. #6
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: oil furnace in the garage.

    Quote Originally Posted by Raymond Wand View Post
    If it supplies interior of home it's wrong because CO can be carried into living space.
    Replying on my phone so hard see about the photo - but isn't the heated air system in a closed loop to/from the living space and separate from the combustion air system in the garage?

    Just like when a furnace is in an attic or basement.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  7. #7
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    I was under impression system is in garage not separate in its own room. Ducting not sealed.

    Robert we need more info to clarify.


  8. #8
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: oil furnace in the garage.

    Quote Originally Posted by Raymond Wand View Post
    I was under impression system is in garage not separate in its own room. Ducting not sealed.

    Robert we need more info to clarify.
    I am also under the impression the system is in the garage and not separate in its own room ... just like it would be in an attic or basement.

    The only time the duct (return air) is not sealed to the unit would be when the unit is in the conditioned space, right?

    Otherwise you would be having to heat the air of whatever temperature was outside (if the unit was in an attic) or whatever the air temperature was in the basement, leading to a very inefficient system trying to heat -40 degree air to 70 degrees, or even trying to heat 40 degree air in a basement to 70 degrees, and having to keep heating fresh air instead of just having to re-heat the environmental air in the conditioned space.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  9. #9
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: oil furnace in the garage.

    Quote Originally Posted by ROBERT YOUNG View Post
    Interior garage.
    Could not locate oil tank.
    Too much stuff.
    Could not get an image with the car removed.
    Plenum, return and supply and branches in the garage.
    Circa 1987 everything.
    Oil tank outside underground somewhere? In an inaccessible compartment off the garage? In a basement?

    Ductwork in a garage needs to be:
    - sealed just like all other ductwork needs to be
    - protected from physical damage
    - insulated just like all other ductwork not in conditioned space needs to be
    - properly supported

    Furnace in garage needs proper combustion air.

    Vent from furnace in garage needs to not be insulated (if that insulted item in the photo is the vent).

    As Raymond said - need more information, paint the picture better for us.

    You guys way up north there need to make sure that silly looking fat guy feeds those weird horses with horn things well, they have a lot of work scheduled for tonight.

    Happy Holidays!

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  10. #10
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    Jerry,

    I was using my phone to look and post about the furnace too.

    Now back on my computer. I agree with your assessment.

    Further concern with duct work at cleats, they are not sealed.

    Also its a power vent exhaust.


  11. #11
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    Circa 1987 everything.
    Okay, so its 29 years old. Its past its due date. Time for upgrades/improvement/replacement ... $$$$


  12. #12
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: oil furnace in the garage.

    Another reference from state side fyi.

    Default Re: Furnace in Garage
    Greetings from COSA, the CARBON MONOXIDE SAFETY ASSOCIATION
    Phone 1-800-394-5253 Website: The Carbon Monoxide Safety Assoc

    See post 23
    http://www.inspectionnews.net/home_i...ce-garage.html

    Fröhliche Weihnachten!


  13. #13
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: oil furnace in the garage.

    Quote Originally Posted by Raymond Wand View Post
    Okay, so its 29 years old. Its past its due date. Time for upgrades/improvement/replacement ... $$$$
    And that's not even including that electrical mess front and center in Roberts photo!

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  14. #14
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: oil furnace in the garage.

    Quote Originally Posted by Raymond Wand View Post
    Another reference from state side fyi.

    Default Re: Furnace in Garage
    Greetings from COSA, the CARBON MONOXIDE SAFETY ASSOCIATION
    Phone 1-800-394-5253 Website: The Carbon Monoxide Safety Assoc

    See post 23
    http://www.inspectionnews.net/home_i...ce-garage.html

    Fröhliche Weihnachten!
    From that post you linked too:

    "But, I will add that open combustion flames present a hazard for combustion gases and by-products (Carbon Monoxide for one) to reach the inhabitants of the dwelling you are inspecting. Forced air furnaces and other Air Handlers that have ductwork in garages can be the pathway to draw in these hazards. "

    Somehow, putting the furnace in the garage is MORE dangerous than putting that very same furnace INSIDE the living space (because carbon monoxide can get into the ductwork from the garage, but it's okay to allow that same carbon monoxide to just roll out into the living space?

    Either I am missing something or he did not think the reply through.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  15. #15
    Join Date
    Oct 2010
    Location
    MONTREAL QUEBEC-CANADA
    Posts
    2,075

    Default Re: oil furnace in the garage.

    Sorry for the late reply.
    Just heading home from last minute shoping.

    Amana/Goodman oil fired furnace.
    Exposed in the garage. Can not locate oil tank.
    Natural draft.
    Single wall with B vent through the wall assembly.
    Ambient combustion air,
    Second time I have seen this type of setup.
    Typically/usually the have there own or in an utility room.

    I will post the model and serial number shortly.
    Fire code?

    Robert Young's Montreal Home Inspection Services Inc.
    Call (514) 489-1887 or (514) 441-3732
    Our Motto; Putting information where you need it most, "In your hands.”

  16. #16
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: oil furnace in the garage.

    Quote Originally Posted by ROBERT YOUNG View Post
    Fire code?
    I don't know about up there, but the IRC requires the ignition source (flame, spark, anything which can ignite something else) be at least 18 inches above the garage floor.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  17. #17
    Join Date
    Oct 2010
    Location
    MONTREAL QUEBEC-CANADA
    Posts
    2,075

    Default Re: oil furnace in the garage.

    Everything appears correct.
    The burner was 18" inches above the flooring.

    Thank you so much for your response members and Merry Christmas.

    Robert Young's Montreal Home Inspection Services Inc.
    Call (514) 489-1887 or (514) 441-3732
    Our Motto; Putting information where you need it most, "In your hands.”

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •