Registration is FREE!... and will get rid of this top message
Welcome to InspectionNews.net.
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.
There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.
Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!
Registration is FREE, fast and easy so please, join InspectionNews today!
Why join InspectionNews? Read the Testimonials
Looking for Education? We recommend Casey, O'Malley and Associates

If you have any problems with the registration process or your account login, please contact us.
|
|

10-20-2009, 04:10 PM
|
|
Member
|
|
Join Date: May 2008
Location: Park City
Posts: 155
|
|
|
Furnace in garage
This furnace is in the garage. The return air registers are in the house. Any recommendations?
Thanks,
Ryan
|
|

10-20-2009, 04:27 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 1,201
|
|
|
Re: Furnace in garage
Originally Posted by Ryan Stouffer
This furnace is in the garage. The return air registers are in the house. Any recommendations? Thanks, Ryan
Ryan,
Not sure what you are looking for. Is there some specific question or do you want us to do your job?
__________________
We have enough youth, how about a fountain of Smart?
|
|

10-20-2009, 05:01 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,296
|
|
|
Re: Furnace in garage
Well, the duct work is metal, required to be 26 gage.
Is that an uninsulated duct going up to the right?
It is not permissible to screw and support the vent and conduit to that metal duct.
Insulation, what is left of it, has the facing exposed and should be covered and protected with drywall.
|
|

10-20-2009, 05:31 PM
|
|
Member
|
|
Join Date: May 2008
Location: Park City
Posts: 155
|
|
|
Re: Furnace in garage
Gunnar, no I am not asking you to do my job. Maybe I should have been more specific and asked are furnaces allowed to be in garages and exposed like this? This is the actual garage that the furnace is sitting in.
|
|

10-20-2009, 06:40 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,296
|
|
|
Re: Furnace in garage
Originally Posted by Ryan Stouffer
are furnaces allowed to be in garages and exposed like this?
Yes, but all the duct connections and connections to the air handler need to be sealed (tape, mastic, or other approved sealant applied in the approved manner).
|
|

10-20-2009, 06:45 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 1,201
|
|
|
Re: Furnace in garage
Originally Posted by Ryan Stouffer
Gunnar, no I am not asking you to do my job. Maybe I should have been more specific and asked are furnaces allowed to be in garages and exposed like this? This is the actual garage that the furnace is sitting in.
Ryan,
Sorry, that came out more harsh than I intended.
Don't forget vehicle protection (bollard).
Can the plenum support the weight of a furnace? I generally see them supported on a wood framed platform with the plenum located under the platform. Guess you don't have earthquakes there.
On an unrelated note, I see a duct running up through the ceiling. Is that living space above without a separation wall?
__________________
We have enough youth, how about a fountain of Smart?
|
|

10-20-2009, 07:10 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Oregon
Posts: 1,335
|
|
|
Re: Furnace in garage
This always makes me laugh when it comes up. It must be a regional thing.... 95% of new construction in my area has the furnaces in the garage. As JP said, the duct penetrations must be 26 gauge. Check fire sealant/taping around vents, ducts and other penetrations to maintain fire separation (gaps around the back of the plenums is a common problem). And, as Gunnar mentioned, vehicle protection.
Those are the main things that come to mind.
|
|

10-20-2009, 07:25 PM
|
|
Member
|
|
Join Date: Mar 2008
Location: Park City, Utah
Posts: 650
|
|
|
Re: Furnace in garage
What about the exposed vent. Just a thought.
|
|

10-20-2009, 08:19 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Near Philly, Pa.
Posts: 815
|
|
|
Re: Furnace in garage
duct sealing
makeup air
bollard
support for everything
__________________
Keep the fire in the fireplace.
|
|

10-21-2009, 12:40 AM
|
|
Member
|
|
Join Date: Jun 2007
Location: Oregon
Posts: 625
|
|
|
Re: Furnace in garage
Crap, I wasted my time responding to the other thread before seeing this one...........
|
|

10-24-2009, 08:20 AM
|
|
Member
|
|
Join Date: Oct 2009
Location: ct
Posts: 3
|
|
|
Re: Furnace in garage
I would be concerned with the lack of a combustion air pipe as storage of chemicals is present in most garages.
|
|