InspectionNews - Home Inspection


Share |

Welcome to InspectionNews.

Registration is FREE!

Why join InspectionNews? Read the Testimonials

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but you will not see any of the pictures or technical bulletins that have been uploaded.

There are over 11,850 inspectors who have already joined InspectionNews, contributing over 100,700 posts. By joining InspectionNews you will be able to see the pictures, start new threads, reply to posts, communicate privately with other members, respond to polls, upload content and access many other special features.

If you are an inspector or thinking about becoming one, InspectionNews is the place for you.

Registration is FREE because the sponsors pay your way.
Please visit all the sponsors often and let them know that you found them on InspectionNews!

How much should an inspection cost? Click the banner below to find out.
The Cost Of Business

If you have any problems with the registration process or your account login, please contact us.

Registration is easy, so please Join InspectionNews Today!

Cost Of Business
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-31-2010, 09:35 AM
Nick Ostrowski Nick Ostrowski is offline
Member
 
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 1,812
Return Duct (NOPE)
Saw this yesterday. The AC was running at the time when I opened this main return air vent on the ceiling (the only return vent in the unit). The filter fell right out. No air draw, no suction. I even put a piece of toilet paper up to the vent to see if it was getting any draw in the least. Nothing. The duct you see running above the vent cover is the supply. All the return air was being pulled from the ceiling cavity between the unit I inspected and the unit above. The builder rep who was there said "if it was wrong, there'd be a problem with the air in here. Look, it's 76 degrees". HUH?????? He also said that two HVAC companies had looked at it said nothing was wrong. Sigh.

The builder rep alos poo-poo'd my calling out of an S-trap on the kitchen sink drain line. He said, you won't get that kind of trap in Philadelphia". Wha........?????????? I asked him what kind of trap will you see. He said "they just want to see a trap". Double sigh.

The shower head supply line in one of the shower stalls had about 2-3 inches of play inside the wall. When I mentioned it to the client, the rep looked at the marble tile surround and said "you know that's not going to get fixed. Look at that marble". Triple sigh.

It's lovely what $400,000 for a condo will get you these days.

Also included are pics of the horizontal balusters on the balcony (4th floor), one strand of the service cable not secured beneath the lug inside the panel box, and arcing on wires at the top of the panel box interior where the cable is rubbing against the bushing clamp.
Attached Images
File Type: jpg return vent.jpg (16.5 KB, 41 views)
File Type: jpg return vent (nope).jpg (45.7 KB, 44 views)
File Type: jpg balusters.jpg (37.2 KB, 47 views)
File Type: jpg service cable.jpg (56.4 KB, 49 views)
File Type: jpg arcing.jpg (40.4 KB, 49 views)
__________________
"It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey
Reply With Quote
FREA Home Inspector Insurance
  #2 (permalink)  
Old 07-31-2010, 10:06 AM
James Duffin James Duffin is offline
Member
 
Join Date: May 2007
Location: NC
Posts: 921
Re: Return Duct (NOPE)
If the ceiling was being used as a return air plenum then there is a few problems that need to be addressed.
Reply With Quote
  #3 (permalink)  
Old 07-31-2010, 10:41 AM
Nick Ostrowski Nick Ostrowski is offline
Member
 
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 1,812
Re: Return Duct (NOPE)
Oh come on James. What's a little bit a fiberglass insulation getting blown around the house going to hurt. And if any of those pipes leak, that's an instant humidifier for the winter.
__________________
"It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey
Reply With Quote
  #4 (permalink)  
Old 07-31-2010, 11:31 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 16,462
Re: Return Duct (NOPE)
With or without using that ceiling space as a return plenum would still require that paper facing to be covered with gypsum board.

As James said, using that ceiling space as a return plenum creates many requirements, and that exposed insulation is just one, as are those exposed wall cavities, and probably a lot of other things which are not in the photos.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #5 (permalink)  
Old 07-31-2010, 12:17 PM
James Duffin James Duffin is offline
Member
 
Join Date: May 2007
Location: NC
Posts: 921
Re: Return Duct (NOPE)
Quote:
Originally Posted by Nick Ostrowski View Post
Oh come on James. What's a little bit a fiberglass insulation getting blown around the house going to hurt. And if any of those pipes leak, that's an instant humidifier for the winter.
Kinda stated the obvious hunh!
Reply With Quote
  #6 (permalink)  
Old 07-31-2010, 12:54 PM
Nick Ostrowski Nick Ostrowski is offline
Member
 
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 1,812
Re: Return Duct (NOPE)
Unfortunately nothing was too obvious for the builder.

The realtor who is very nice and sends me a few jobs a year said 4-5 other units just like this one in the same building were sold and the inspections were spotless. What are the chances I got the only lemon in the bunch?
__________________
"It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey
Reply With Quote
  #7 (permalink)  
Old 07-31-2010, 02:32 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 16,462
Re: Return Duct (NOPE)
Quote:
Originally Posted by Nick Ostrowski View Post
and the inspections were spotless.

Did you tell her that your reports are spotless too ... ... until someone spills coffee or something on them.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
Cost Of Business
Reply

Share |

Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Inlet Duct Ken Milton Attic Areas: Home Inspection and Commercial Inspection 19 02-25-2010 05:01 PM
Unlined Return Duct Bruce Ramsey Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 32 10-13-2009 04:13 PM
Return air duct passing through firewall Ron Bishop Exterior Systems: Home Inspection and Commercial Inspection 5 06-09-2009 05:53 PM
HVAC Return Jumper Duct from Garage ? Nolan Kienitz Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 10 01-02-2009 11:11 AM
Humidifier on return duct fritzkelly Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 16 09-03-2008 12:56 PM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 11:45 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2010, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.