Welcome to InspectionNews.
Registration is FREE!
Why join InspectionNews? Read the Testimonials
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but you will not see any of the pictures or technical bulletins that have been uploaded.
There are over 11,850 inspectors who have already joined InspectionNews, contributing over 100,700 posts. By joining InspectionNews you will be able to see the pictures, start new threads, reply to posts, communicate privately with other members, respond to polls, upload content and access many other special features.
If you are an inspector or thinking about becoming one, InspectionNews is the place for you.
Registration is FREE because the sponsors pay your way.
Please visit all the sponsors often and let them know that you found them on InspectionNews!
How much should an inspection cost? Click the banner below to find out.

If you have any problems with the registration process or your account login, please contact us.
Registration is easy, so please Join InspectionNews Today!
|
 |
 |
|
 |
|

07-31-2010, 09:35 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 1,812
|
|
|
Return Duct (NOPE)
Saw this yesterday. The AC was running at the time when I opened this main return air vent on the ceiling (the only return vent in the unit). The filter fell right out. No air draw, no suction. I even put a piece of toilet paper up to the vent to see if it was getting any draw in the least. Nothing. The duct you see running above the vent cover is the supply. All the return air was being pulled from the ceiling cavity between the unit I inspected and the unit above. The builder rep who was there said "if it was wrong, there'd be a problem with the air in here. Look, it's 76 degrees". HUH?????? He also said that two HVAC companies had looked at it said nothing was wrong. Sigh.
The builder rep alos poo-poo'd my calling out of an S-trap on the kitchen sink drain line. He said, you won't get that kind of trap in Philadelphia". Wha........?????????? I asked him what kind of trap will you see. He said "they just want to see a trap". Double sigh.
The shower head supply line in one of the shower stalls had about 2-3 inches of play inside the wall. When I mentioned it to the client, the rep looked at the marble tile surround and said "you know that's not going to get fixed. Look at that marble". Triple sigh.
It's lovely what $400,000 for a condo will get you these days.
Also included are pics of the horizontal balusters on the balcony (4th floor), one strand of the service cable not secured beneath the lug inside the panel box, and arcing on wires at the top of the panel box interior where the cable is rubbing against the bushing clamp.
__________________
"It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey
|
|

07-31-2010, 10:06 AM
|
|
Member
|
|
Join Date: May 2007
Location: NC
Posts: 921
|
|
|
Re: Return Duct (NOPE)
If the ceiling was being used as a return air plenum then there is a few problems that need to be addressed.
|
|

07-31-2010, 10:41 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 1,812
|
|
|
Re: Return Duct (NOPE)
Oh come on James. What's a little bit a fiberglass insulation getting blown around the house going to hurt. And if any of those pipes leak, that's an instant humidifier for the winter. 
__________________
"It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey
|
|

07-31-2010, 11:31 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 16,462
|
|
|
Re: Return Duct (NOPE)
With or without using that ceiling space as a return plenum would still require that paper facing to be covered with gypsum board.
As James said, using that ceiling space as a return plenum creates many requirements, and that exposed insulation is just one, as are those exposed wall cavities, and probably a lot of other things which are not in the photos.
|
|

07-31-2010, 12:17 PM
|
|
Member
|
|
Join Date: May 2007
Location: NC
Posts: 921
|
|
|
Re: Return Duct (NOPE)
Originally Posted by Nick Ostrowski
Oh come on James. What's a little bit a fiberglass insulation getting blown around the house going to hurt. And if any of those pipes leak, that's an instant humidifier for the winter. 
Kinda stated the obvious hunh! 
|
|

07-31-2010, 12:54 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 1,812
|
|
|
Re: Return Duct (NOPE)
Unfortunately nothing was too obvious for the builder.
The realtor who is very nice and sends me a few jobs a year said 4-5 other units just like this one in the same building were sold and the inspections were spotless. What are the chances I got the only lemon in the bunch?
__________________
"It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey
|
|

07-31-2010, 02:32 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 16,462
|
|
|
Re: Return Duct (NOPE)
Originally Posted by Nick Ostrowski
and the inspections were spotless.
Did you tell her that your reports are spotless too ...  ... until someone spills coffee or something on them.
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Inlet Duct |
Ken Milton |
Attic Areas: Home Inspection and Commercial Inspection |
19 |
02-25-2010 05:01 PM |
| Unlined Return Duct |
Bruce Ramsey |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
32 |
10-13-2009 04:13 PM |
| Return air duct passing through firewall |
Ron Bishop |
Exterior Systems: Home Inspection and Commercial Inspection |
5 |
06-09-2009 05:53 PM |
| HVAC Return Jumper Duct from Garage ? |
Nolan Kienitz |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
10 |
01-02-2009 11:11 AM |
| Humidifier on return duct |
fritzkelly |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
16 |
09-03-2008 12:56 PM |
All times are GMT -7. The time now is 11:45 PM.
| | |
|