You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-24-2007, 07:02 PM
Trent Tarter Trent Tarter is offline
Member
 
Join Date: Mar 2007
Location: Washington State
Posts: 73
Scary looking vent pipe.
This is in original 1930 oil furnace converted to gas. The flue pipe has a box or some type of damper installed. It is open on the bottom, I would think that something is missing here. Has anybody seen anything like this before?
Attached Images
File Type: jpg 821 Hobson 022.jpg (16.6 KB, 55 views)
File Type: jpg 821 Hobson 023.jpg (13.5 KB, 45 views)
Reply With Quote
  #2 (permalink)  
Old 07-24-2007, 07:20 PM
David Banks David Banks is offline
Member
 
Join Date: Mar 2007
Location: Southborough, MA
Posts: 912
Re: Scary looking vent pipe.
I believe what you have there is a draft diverter that is on vent instead of part of furnace unit itself.
__________________
Dave
Reply With Quote
  #3 (permalink)  
Old 07-24-2007, 07:55 PM
Gary Schutta Gary Schutta is offline
Member
 
Join Date: Mar 2007
Posts: 3
Re: Scary looking vent pipe.
That is an old draft diverter & should of been capped off so the new gas furnace will draft properly.

Gary
Reply With Quote
  #4 (permalink)  
Old 07-25-2007, 04:38 PM
DavidR's Avatar
DavidR DavidR is offline
Member
 
Join Date: May 2007
Location: Frankfort, KY
Posts: 160
Re: Scary looking vent pipe.
If that is a homemade drafthood it is as illegal as the day is long.

It has to have an AGA stamp on it to be approved, besides a double acting barometric would be much more effective.
__________________
Measured Performance more than just a buzzword
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Australian Vent pipe wayne soper Plumbing System: Home Inspection and Commercial Inspection 2 07-19-2007 05:08 AM
Vent pipe wayne soper Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 4 07-01-2007 05:39 PM
Flex vent pipe John Stephenson Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 7 05-29-2007 09:57 AM
Foil tape on vent pipe Jeff Eastman Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 5 05-18-2007 04:12 PM
Upsized water heater vent pipe Jeff Eastman Plumbing System: Home Inspection and Commercial Inspection 2 04-30-2007 10:32 AM


All times are GMT -7. The time now is 04:40 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger