You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-30-2007, 06:54 AM
Kevin VanderWarf's Avatar
Kevin VanderWarf Kevin VanderWarf is offline
Member
 
Join Date: Mar 2007
Location: Aiken S.C.
Posts: 130
Flu blowing on gas union
This looks a poor design to me, but with that in mind I certainly would have put my union and shut off valve someplace else.

This is a Trane gas pack, never seen one like it must be new. It looks like the exhaust fitting is mounted properly. With the configuration of the gas line entrance and the exhaust, it looks like you would find flu gas blowing on the gas line one way or another. Unless the gas line were run low or buried.
Either way it looks like a little of both, design and installer error
Attached Images
File Type: jpg HPIM1238.jpg (41.2 KB, 52 views)
File Type: jpg HPIM1239.jpg (33.8 KB, 49 views)
__________________
Consistency is a direct path to perfection.
Reply With Quote
  #2 (permalink)  
Old 07-30-2007, 03:30 PM
DavidR's Avatar
DavidR DavidR is offline
Member
 
Join Date: May 2007
Location: Frankfort, KY
Posts: 176
Re: Flu blowing on gas union
Wonder how much of that flue gas is making it back into the burner compartment?
__________________
Measured Performance more than just a buzzword
Reply With Quote
  #3 (permalink)  
Old 08-29-2007, 09:37 AM
Kevin VanderWarf's Avatar
Kevin VanderWarf Kevin VanderWarf is offline
Member
 
Join Date: Mar 2007
Location: Aiken S.C.
Posts: 130
Re: Flu blowing on gas union
Gotta try and get more feed back on this thread. I posted it a few weeks back and didn't much response.
I ran into the same problem on another job yesterday.
The flu is blowing directly on the non-galvanized, unpainted gas line.
That exhaust is acidic right? This can't be a good setup.
I recommended that the gas line be re-routed and painted, I don't see where the flu vent could be changed.
__________________
Consistency is a direct path to perfection.
Reply With Quote
  #4 (permalink)  
Old 08-29-2007, 01:18 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is offline
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 1,602
Re: Flu blowing on gas union
I checked TRANE web site. Owners manual with install guide shows Flue pointing up
and a vent cover on gas intake pointed down. Sorry no link Model# XL16009ycz).
Reflection in your picture looks like there is a gap between cabinet and electrical entry.


Billy
Reply With Quote
  #5 (permalink)  
Old 08-29-2007, 03:09 PM
DavidR's Avatar
DavidR DavidR is offline
Member
 
Join Date: May 2007
Location: Frankfort, KY
Posts: 176
Re: Flu blowing on gas union
Quote:
Originally Posted by Kevin VanderWarf View Post
That exhaust is acidic right? This can't be a good setup.
Has a ph of approximately 4.
__________________
Measured Performance more than just a buzzword
Reply With Quote
  #6 (permalink)  
Old 08-29-2007, 04:19 PM
Kevin VanderWarf's Avatar
Kevin VanderWarf Kevin VanderWarf is offline
Member
 
Join Date: Mar 2007
Location: Aiken S.C.
Posts: 130
Re: Flu blowing on gas union
Billy,

So your saying the black plastic piece should point up? It looked kinda rectangular so I didn't think it would mount 90degrees from from it's present position.
Well, that's good to know and it's a simple fix.

Anyway, the HVAC contractor doesn't appear to be in the habit of leaving the manuals behind.
Thanks for your help.
__________________
Consistency is a direct path to perfection.

Last edited by Kevin VanderWarf : 08-29-2007 at 04:47 PM.
Reply With Quote
  #7 (permalink)  
Old 08-29-2007, 04:44 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is offline
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 1,602
Re: Flu blowing on gas union
Kevin,

The one model I checked had the( Black plastic ) vent pointed up. There was also a cover on the gas intake with the opening for intake air pointed down. Looking at your picture
not sure if there is room to install this cover without rerouteing gas line. Might want to find
the Model # in question installation instructions for proper install for your report reference.


Billy
Reply With Quote
  #8 (permalink)  
Old 08-29-2007, 04:56 PM
Kevin VanderWarf's Avatar
Kevin VanderWarf Kevin VanderWarf is offline
Member
 
Join Date: Mar 2007
Location: Aiken S.C.
Posts: 130
Re: Flu blowing on gas union
Billy,
I gonna recommend that both clients get a 2nd opinion on the entire system.
The original contractor thinks everything is fine.
Both systems also have excessive sweating on the compressor. I'm told that this may very well be a duct design (beyond my scope) problem.
But your info has been very helpful in finishing my report and giving the 2nd opinion guy some direction.
I think I'm gonna leave it at that.
__________________
Consistency is a direct path to perfection.
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



All times are GMT -7. The time now is 11:00 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger