You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

04-05-2007, 09:42 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Agoura Hills, CA
Posts: 99
|
|
|
Vent Tee
Okay sleuths. Here is a photo of a vent tee that combines furnace and water heater venting at the garage. It appears to have been (1) installed upside down, and (2) cut/modified/altered contrary to manufacturer specifications.
As I stare at the photo a little longer, I think it may be just a sleeve and there is no defect at all. The house was built in 1999 and probably looked this way when the builder got his C of O. What's your opinion?
|
|

04-05-2007, 10:00 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: New Port Richey, Fl
Posts: 446
|
|
|
Re: Vent Tee
I agree on the sleeve part, but why would you need one?
Never saw that before.
|
|

04-05-2007, 11:01 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,751
|
|
|
Re: Vent Tee
It looks like someone has cut a "B" vent pipe to insert the "tee". Any modification of a "B" vent is a red flag. What is stopping the flue gas from rolling back down and out the bottom of that sleeve? Nothing from what I can see.
I would call it out as being an improper vent connection. It does not matter that it was that way when the builder got his CO on the home.
|
|

04-05-2007, 07:36 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Pa.
Posts: 577
|
|
|
I'm Tee'd off
Bingo Scott! This is a major hack job. Did a Vega-matic on the B-vent because they were too cheap/ stupid to get the proper B-vent tee and manifold them together. That section of B-vent along with this abortion of piping must be replaced.
I would take this photo to the building dept. and ask them what they thnk of it. If they state it is ok, hit them on the noggin with the photo. The only way someone with any clue whatsoever could pass this is if they were living in this home and were stoned from the CO fumes. A really dangerous situation.
After you discuss this with them, them pose this question: So, having seen this attempt at manslaughter, how many other similar jobs do you think this tech did in your jurisdiction?
This really ticks me off. Can you tell?
__________________
disgusted with some people on this forum. Out of here!
|
|

04-05-2007, 08:28 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,396
|
|
|
Re: Vent Tee
Bob,
You'll be more upset when you see these.
Someone had told the seller the WH flue needed to be strapped when they bought the home 12 years ago, so her husband repaired it himself.
And then there was the furnace flue terminating in the attic.
__________________
Rick Hurst_Home Works Inspection Co_Rockwall TX
In the words of Mike Tyson.... "Everyone has a plan until they get hit inda mouf"
|
|

04-05-2007, 09:58 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
|
|
|
Re: Vent Tee
Dang, Rick! You kept that guy from qualifying for the Darwin Awards. Shame on you!
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

04-05-2007, 10:05 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Pa.
Posts: 577
|
|
|
Re: Vent free
They should'a woke up dead. Unreal how much of this insanity there is out there.
__________________
disgusted with some people on this forum. Out of here!
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Crawlspace vent fan |
Kevin Luce |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
11 |
05-18-2007 09:13 PM |
| Roof Jack w/ Neoprene Boot At B Vent |
Bruce Breedlove |
Roofing System: Home Inspection and Commercial Inspection |
6 |
04-03-2007 02:14 PM |
All times are GMT -7. The time now is 11:49 AM.
| | |
|
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by
RedTyger