InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 12-23-2007, 10:54 AM
Jim Kasterko Jim Kasterko is offline
Member
 
Join Date: Mar 2007
Location: Southern Maryland
Posts: 30
HVAC in Kitchen
I was a taken back when I saw the HVAC unit and water heater installed in the kitchen, a first for me. I checked the IRC and I believe I found the places they could not be, which didn’t include a kitchen. So, are there any technical or safety type reasons not to install these units in a kitchen? Also, I’m having trouble determining the age of the Sears/Dunkirk boiler (series PW41 Model 229 963440 Serial 29830015). Thanks in advance.
Attached Images
File Type: jpg HVAC_IN_Kitchen.jpg (44.8 KB, 203 views)
__________________
Jim, in Calvert County, MD
Reply With Quote
Home Inspector Essentials. The BEST prices for inspection tools.
  #2 (permalink)  
Old 12-23-2007, 12:32 PM
imported_John Smith imported_John Smith is offline
Member
 
Join Date: Mar 2007
Location: Alvin Texas
Posts: 487
Re: HVAC in Kitchen
Photo Shop is a great software package.
Reply With Quote
  #3 (permalink)  
Old 12-23-2007, 02:21 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: HVAC in Kitchen
Quote:
Originally Posted by Jim Kasterko View Post
I’m having trouble determining the age of the Sears/Dunkirk boiler (series PW41 Model 229 963440 Serial 29830015). Thanks in advance.
Quote:
Originally Posted by imported_John Smith View Post
Photo Shop is a great software package.
29th

John,
If it's a staged photo he made the flash shadows also (Look at top of Sink)

Jim,

The Dunkirk Boiler was made in the 29yh week of 1983.

Your photo shows a water heater and a Boiler.

Help me understand the AC part.

There are numerous things
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #4 (permalink)  
Old 12-23-2007, 04:16 PM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: HVAC in Kitchen
Quote:
Originally Posted by Billy Stephens View Post
Your photo shows ... a Boiler.

Help me understand the AC part.
Billy,

HVAC refers to that type of equipment as it falls under HVAC (i.e., "mechanical"), and the 'H' in HVAC stands for (as you already know) "Heating" - which that is. Thus, it is HVAC 'equipment'.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #5 (permalink)  
Old 12-23-2007, 07:43 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,691
Re: HVAC in Kitchen
Around here (Chicago and suburbs) I frequently see the HVAC, hot water and/or laundry in a utility closet off the kitchen - usually there are louvered doors, but sometmes it's just open to the kitchen. Same, thing, if you think about it.
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #6 (permalink)  
Old 12-23-2007, 08:07 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,655
Re: HVAC in Kitchen
Thats one of the worst photoshop pics I've seen.

rick
__________________
This space is now available for sale or for lease. Contact your broker if interested. Serious inquiries only.
Reply With Quote
  #7 (permalink)  
Old 12-24-2007, 08:49 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: HVAC in Kitchen
The first house I owned was built in 1894. The gas water heater was in the kitchen (in a corner of the kitchen). The heater was an old kerosene burner smack in the living room. I'm talking about one of those old ones in which the kerosene pooled in the bottom and was ignited, burning on its own, with the control being a 'flow valve' which controlled the amount of kerosene which would flow down into the fire bowl, gravity fed from a higher tank outside. There was no pump/spray/atomizer, just kerosene in a bowl burning and putting off heat within its fire-pot and cabinet. And not a lot of heat at that. On colder nights we had to sleep in the living room.

That was in Gainesville, Florida, and it would get into the teens there. Was always having pipes freeze if we did not leave the water running fast enough (fortunately, no broken pipes while we lived there).

The clothes washer was on the screened rear porch.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #8 (permalink)  
Old 12-24-2007, 09:59 AM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,691
Re: HVAC in Kitchen
Rick,

Over on TIJ that load fill size (500K) and does not appear 'Shopped to me.
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #9 (permalink)  
Old 12-24-2007, 10:54 AM
Jim Kasterko Jim Kasterko is offline
Member
 
Join Date: Mar 2007
Location: Southern Maryland
Posts: 30
Re: HVAC in Kitchen
Ok,... How did I screw up the photo?
__________________
Jim, in Calvert County, MD
Reply With Quote
  #10 (permalink)  
Old 12-24-2007, 11:03 AM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: HVAC in Kitchen
Quote:
Originally Posted by Jim Kasterko View Post
Ok,... How did I screw up the photo?
Jim,

I think the questions about the Photo is it a single picture or a combination of 2 or more photos?
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #11 (permalink)  
Old 12-24-2007, 12:11 PM
Jim Kasterko Jim Kasterko is offline
Member
 
Join Date: Mar 2007
Location: Southern Maryland
Posts: 30
Re: HVAC in Kitchen
Ok,... How did I screw up the photo?
__________________
Jim, in Calvert County, MD
Reply With Quote
  #12 (permalink)  
Old 12-24-2007, 12:13 PM
Jim Kasterko Jim Kasterko is offline
Member
 
Join Date: Mar 2007
Location: Southern Maryland
Posts: 30
Re: HVAC in Kitchen
oooppps. It was a single photo.
__________________
Jim, in Calvert County, MD
Reply With Quote
  #13 (permalink)  
Old 12-24-2007, 12:32 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,691
Re: HVAC in Kitchen
Some people think it may be "Photoshopped"

The World’s Most Famous Photoshop Fakes | Make Money Selling Your Photos
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #14 (permalink)  
Old 12-26-2007, 07:23 AM
Robert Dalga's Avatar
Robert Dalga Robert Dalga is offline
Member
 
Join Date: Mar 2007
Location: Kalamazoo, MI
Posts: 83
Re: HVAC in Kitchen
I guess I don't get it??? Why would an inspector post a photoshopped photo??? Isn't Jim merely asking for some advise? I see a HUGE safety concern with the mechanicals installed in the kitchen like this. The boiler poses the greatest concern. The potoential for CO emissions from the combustion chamber if a range hood (or ceiling exhaust fan) were running, for example. Furthermore, small children in the vicinity of the boiler could be burned from the exposed equipment.
__________________
RJDalga
http://homeanalysts.com
Kalamazoo, MI
Reply With Quote
  #15 (permalink)  
Old 12-26-2007, 07:00 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: HVAC in Kitchen
Quote:
Originally Posted by Robert Dalga View Post
Furthermore, small children in the vicinity of the boiler could be burned from the exposed equipment.
Or electrocuted from the Loose & unsecured wiring.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #16 (permalink)  
Old 01-08-2008, 07:40 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,691
Re: HVAC in Kitchen
Quick question for Jerry or someone else with the codes on CD: where is the minimum separation of a cold air return from a GFAF specified.

And where is the distance measured from? The draft hood?

- Thanks
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
  #17 (permalink)  
Old 01-09-2008, 06:45 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: HVAC in Kitchen
Michael,

From the 2006 IRC. (bold and underlining are mine)

- M1602.2 Prohibited sources. Outdoor and return air for a forced-air heating or cooling system shall not be taken from the following locations:
- - 1. Closer than 10 feet (3048 mm) to an appliance vent outlet, a vent opening from a plumbing drainage system or the discharge outlet of an exhaust fan, unless the outlet is 3 feet (914 mm) above the outside air inlet.
- - 2. Where flammable vapors are present; or where located less than 10 feet (3048 mm) above the surface of any abutting public way or driveway; or where located at grade level by a sidewalk, street, alley or driveway.
- - 3. A room or space, the volume of which is less than 25 percent of the entire volume served by such system. Where connected by a permanent opening having an area sized in accordance with ACCA Manual D, adjoining rooms or spaces shall be considered as a single room or space for the purpose of determining the volume of such rooms or spaces.
- - - Exception:The minimum volume requirement shall not apply where the amount of return air taken from a room or space is less than or equal to the amount of supply air delivered to such room or space.
- - 4. A closet, bathroom, toilet room, kitchen, garage, mechanical room, furnace room or other dwelling unit.
- - 5. A room or space containing a fuel-burning appliance where such room or space serves as the sole source of return air.
- - - Exceptions:
- - - - 1. The fuel-burning appliance is a direct-vent appliance or an appliance not requiring a vent in accordance with Section M1801.1 or Chapter 24.
- - - - 2. The room or space complies with the following requirements:
- - - - - 2.1. The return air shall be taken from a room or space having a volume exceeding 1 cubic foot for each 10 Btu/h (9.6 L/W) of combined input rating of all fuel-burning appliances therein.
- - - - - 2.2. The volume of supply air discharged back into the same space shall be approximately equal to the volume of return air taken from the space.
- - - - - 2.3. Return-air inlets shall not be located within 10 feet (3048 mm) of any appliance firebox or draft hood in the same room or space.
- - - - 3. Rooms or spaces containing solid-fuel burning appliances, provided that return-air inlets are located not less than 10 feet (3048 mm) from the firebox of such appliances.

Note that those listed under 5. (underlined) *are not* applicable *unless* "room or space serves as the sole source of return air."
I believe that some of these may often be mis-used by applying them to locations where the return air inlet *is not the sole source* of return air.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #18 (permalink)  
Old 04-01-2008, 05:26 PM
Michael Thomas's Avatar
Michael Thomas Michael Thomas is offline
Member
 
Join Date: Mar 2007
Location: Chicago, IL
Posts: 1,691
Re: HVAC in Kitchen
The "decorator" version:
Attached Images
File Type: jpg jponacid.jpg (140.1 KB, 24 views)
__________________
Michael Thomas
Paragon Property Services Inc., Chicago IL
http://paragoninspects.com
Reply With Quote
Home inspection - The Cost Of Business.
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
HVAC return air William Mize Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 2 08-10-2007 03:24 PM
HVAC Help Please Matt Hawley Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 17 07-27-2007 12:17 PM
HVAC disconnect M Kelekci Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 4 07-06-2007 09:04 PM
Three Stooges HVAC wayne soper Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 11 06-22-2007 04:23 PM
new HVAC techs among us Jerry Peck Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 72 05-13-2007 07:22 AM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 01:56 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger