You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 01-30-2008, 04:27 AM
Nick Ostrowski Nick Ostrowski is offline
Member
 
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 699
Breaks in Duct Chase
I saw this in a new construction home yesterday. The view is of the duct chase from inside the crawlspace as it runs up through the 1st and 2nd floors eventually into the attic. The chase walls are drywalled but there were multiple breaks in the drywall exposing wood framing for the walls above. What is the standard or requirement for duct chases like this and do the breaks in the dyrwall necessitate repairs?
Attached Images
File Type: jpg ductchase.jpg (45.7 KB, 29 views)
Reply With Quote
  #2 (permalink)  
Old 01-30-2008, 06:40 AM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,547
Re: Breaks in Duct Chase
Man, that's one fast way to get a fire from the crawlspace to the attic and burn the house down.

Combine that with those openings you described and you are asking for a fire disaster.

That should be firestopped at each floor/ceiling.

If they were trying to make a chase / shaft, they should use the correct board, typically two layers around the outside with studs then another core board around the inside, of course, though, that would also need 26 gage metal duct in it.

It also looks like the duct board is not mechanically connected to each other, not with the two sections/sizes not meeting well like that.
__________________
Jerry Peck, Construction / Litigation Consultant
Ormond Beach, Florida
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #3 (permalink)  
Old 01-30-2008, 09:40 AM
Nick Ostrowski Nick Ostrowski is offline
Member
 
Join Date: Mar 2007
Location: Spring City/Surrounding Philadelphia area
Posts: 699
Re: Breaks in Duct Chase
Thanks Jerry.
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Panel in Return Chase? Clay E White Electrical Systems: Home Inspection and Commercial Inspection 2 09-29-2007 11:49 AM
A/c piping in electrical chase allen elliott Electrical Systems: Home Inspection and Commercial Inspection 3 08-22-2007 12:11 PM
insulated chase Jim McClendon Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 9 07-29-2007 06:10 AM
Electrical cable inside of chimney chase dan orourke Electrical Systems: Home Inspection and Commercial Inspection 3 07-18-2007 08:29 PM
Electrical cable in Chimney Chase John Stephenson Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 13 06-22-2007 07:24 AM


All times are GMT -7. The time now is 07:26 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger