Registration is FREE!... and will get rid of this top message
Welcome to InspectionNews.net.
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.
There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.
Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!
Registration is FREE, fast and easy so please, join InspectionNews today!
Why join InspectionNews? Read the Testimonials
Looking for Education? We recommend Casey, O'Malley and Associates

If you have any problems with the registration process or your account login, please contact us.
|
|

04-16-2007, 10:37 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Florence, SC
Posts: 91
|
|
|
return over range in kitchen
Any idea why a return was installed over the range with another return only 3ft. away in the hall behind the kitchen wall?
__________________
"I reject your reality and substitute my own!" - A. S.
Absolute Home Inspections, LLC
|
|

04-16-2007, 10:43 PM
|
|
|
|
Re: return over range in kitchen
Wes,
I've seen some custom homes that had 4 or 5 returns spread out in the house.
I would think that that is a poor choice of locataions for that one.
I guess if you forget to turn on the exhause hood, the return will catch it for you if your air is on 
Last edited by Tim Moreira : 04-16-2007 at 10:44 PM.
Reason: speeling
|
|

04-17-2007, 01:07 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Seattle, WA
Posts: 349
|
|
|
Re: return over range in kitchen
Looks like just a re-circulating fan at that BI micro-wave(?). If that's their answer to venting moisture and it's actually connected to the return air...then just plain dumb and unsanitary.
Although...you could probably make soup from the furnace filter about once a month! Yummy!
|
|

04-17-2007, 05:23 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Land of Gar, TX
Posts: 418
|
|
|
Re: return over range in kitchen
At least the filter is accessible.
Try this one with reversed access for filter replacement.
2 years without a filter didn't help the evap. coils much.
__________________
badair http://www.adairinspection.com Garland, TX 75042
Residential-Commercial-Construction-EIFS-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes
|
|

04-17-2007, 11:06 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,291
|
|
|
Re: return over range in kitchen
From the IRC.
- SECTION M1602
- - RETURN AIR - - M1602.2 Prohibited sources. Outdoor and return air for a forced-air heating or cooling system shall not be taken from the following locations:
- - - 4. A closet, bathroom, toilet room, kitchen, garage,
mechanical room, furnace room or other dwelling unit.
|
|

04-18-2007, 04:13 AM
|
|
Member
|
|
Join Date: Mar 2007
Posts: 15
|
|
|
Re: return over range in kitchen
I was thinking what Jerry said, besides, it's just a bad idea. Write it up.
|
|

04-18-2007, 04:50 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Florence, SC
Posts: 91
|
|
|
Re: return over range in kitchen
Thanks guys.
__________________
"I reject your reality and substitute my own!" - A. S.
Absolute Home Inspections, LLC
|
|

04-18-2007, 06:43 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Canandaigua New York
Posts: 131
|
|
|
Re: return over range in kitchen
Return air runs in any kitchen, bathroom are not generally done by professional HVAC guys. Who wants the smell of tonights fish dinner in the bedrooms? That is generally the reason for no RA runs in these area's, not counting dad's refreshing smells from the reading room.
__________________
Well thats my 2 cents.
Brian Kelly
Kelly Home Inspections
|
|

04-18-2007, 12:16 PM
|
|
|
|
Re: return over range in kitchen
That is generally the reason for no RA runs in these area's, not counting dad's refreshing smells from the reading room.
So that's why the bathrooms are supposed to have exhaust fans???
(that moisture bit about taking showers is just secondary  )
|
|

04-18-2007, 03:47 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,291
|
|
|
Re: return over range in kitchen
Why do you think bathroom exhaust fans are commonly referred to as "fart fans"? 
|
|

04-18-2007, 07:19 PM
|
|
|
|
Re: return over range in kitchen
assooo grasshopper 
|
|

04-18-2007, 11:01 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,097
|
|
|
Re: return over range in kitchen
"assooo"
Somebody is talking bad about grasshopper...
Rich
|
|

04-19-2007, 01:04 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,291
|
|
|
Re: return over range in kitchen
Originally Posted by Richard Rushing
"assooo"
Somebody is talking bad about grasshopper...
Rich
Nah, there would be an 'h' in there then ... 
|
|

04-26-2007, 10:23 AM
|
|
Member
|
|
Join Date: Mar 2007
Posts: 29
|
|
|
Re: return over range in kitchen
The smell has nothing to do with return air ducts not permitted in kitchens, nor the filter becoming a grease trap.
The picture is self explanitory. Where do you think the smoke and flames from a grease fire on the range will immediately go? The kitchen fire quickly becomes a fully involved fire.
The Mechanical Code prohibits return air ducts within 10 feet of a cooking surface. My pesumption as to why the same language is non-existant in the Res Code is few 'kitchens' have 10 feet in any direction from the range.
|
|

04-27-2007, 10:56 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Canandaigua New York
Posts: 131
|
|
|
Re: return over range in kitchen
If the code stated that no RA grills in the kitchen area's only then I would agree with you, but the code states closets,bathrooms and there are very low percentages that a fire will start in these places. Another point is that if this was to stop the spread of fire then there should be a fire damper in the supply air registers in the kitchen area.
__________________
Well thats my 2 cents.
Brian Kelly
Kelly Home Inspections
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Return for repairs, Stinger Strion? |
Tim Moreira |
Tools and Equipment |
5 |
08-29-2008 03:46 PM |
| Return Air |
David Banks |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
24 |
05-12-2007 05:27 AM |
| Kitchen vent |
Jeff Eastman |
Attic Areas: Home Inspection and Commercial Inspection |
5 |
04-30-2007 06:42 PM |
| range hood |
william siegel |
Built-In Appliances and Systems: Home Inspection and Commercial Inspection |
1 |
04-10-2007 06:36 PM |
All times are GMT -7. The time now is 06:50 PM.
| | |
|