You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 02-11-2008, 02:58 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 145
CSST required at gas applicances
I thought there was a requirement that flexible gas line had to be installed just before a gas appliance to provide some wiggle room during earth quakes. The water heater and attic furnance had CSST installed but the exterior gas pack was missing the CSST. I could not find any mention in Code Check. Don't have complete mechanical codes.

I seem to remember a discussion about the unfitness of CSST for exterior use in this application but could not find the discussion.

Is CSST or similar material required before gas applicances? Any code references?
Attached Images
File Type: jpg 042.JPG (76.7 KB, 70 views)
File Type: jpg 040.jpg (29.2 KB, 51 views)
File Type: jpg 051.jpg (28.5 KB, 45 views)
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
Home inspection
  #2 (permalink)  
Old 02-11-2008, 03:11 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,751
Re: CSST required at gas applicances
Quote:
Originally Posted by Bruce Ramsey View Post
I thought there was a requirement that flexible gas line had to be installed just before a gas appliance to provide some wiggle room during earth quakes. The water heater and attic furnance had CSST installed but the exterior gas pack was missing the CSST. I could not find any mention in Code Check. Don't have complete mechanical codes.

I seem to remember a discussion about the unfitness of CSST for exterior use in this application but could not find the discussion.

Is CSST or similar material required before gas applicances? Any code references?
I think it all depends on the area you are in and what the AHJ requires. Black pipe is OK in my area of TN.

Are you in an earthquake prone area?
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #3 (permalink)  
Old 02-11-2008, 03:32 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 145
Re: CSST required at gas applicances
The house is in Wake County of North Carolina (category B in the seismic table). Technically the house is located in the city of Holly Springs, which is really an outlying 'burb of Raleigh. Zipcode 27540.

Not sure where to look for gas line rules with regards to seismic tables.
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
  #4 (permalink)  
Old 02-11-2008, 04:27 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 1,751
Re: CSST required at gas applicances
Quote:
Originally Posted by Bruce Ramsey View Post
The house is in Wake County of North Carolina (category B in the seismic table). Technically the house is located in the city of Holly Springs, which is really an outlying 'burb of Raleigh. Zipcode 27540.

Not sure where to look for gas line rules with regards to seismic tables.
I would not loose any sleep over this as it is most likely a non-issue. I would contact the AHI in the area that covers the house and ask them. They will have the final answer.
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #5 (permalink)  
Old 02-11-2008, 06:34 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,644
Re: CSST required at gas appliances
Quote:
Originally Posted by Bruce Ramsey View Post
The house is in Wake County of North Carolina (category B in the seismic table).
Bruce,

From the 2006 IRC. (underlining is mine)

- R301.2.2 Seismic provisions. The seismic provisions of this code shall apply to buildings constructed in Seismic Design Categories C, D0, D1 and D2, as determined in accordance with this section. Buildings in Seismic Design Category E shall be designed in accordance with the International Building Code, except when the seismic design category is reclassified to a lower seismic design category in accordance with Section R301.2.2.1.
- Exception: Detached one- and two-family dwellings located in Seismic Design Category C are exempt from the seismic requirements of this code.

If you are in seismic category B, apparently, nothing applies (the IRC does not apply, seismically speaking, to category B).
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #6 (permalink)  
Old 02-11-2008, 06:48 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 145
Re: CSST required at gas applicances
Terrific. Thank you!
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
  #7 (permalink)  
Old 02-13-2008, 04:51 PM
Mike Schulz's Avatar
Mike Schulz Mike Schulz is offline
Member
 
Join Date: Mar 2007
Location: Fuquay Varina, NC
Posts: 461
Re: CSST required at gas applicances
Earhtquakes..............NC...............with the way the weather has been the last couple of years anything is possible.

Funny thing is if we did have a earthquake now it would be 2012 before the code would change............

Bruce many of the homes have CSST because it much easier to install then black pipe. That is why you don't normally see it except on older homes. Don't have to lug around all that steel and threading machines.
__________________
Mike Schulz License 393
Affordable Home Inspections
www.houseinspections.com
Reply With Quote
  #8 (permalink)  
Old 02-13-2008, 07:15 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 145
Re: CSST required at gas applicances
On newer construction I see black pipe from the meter to the CSST manifold in the crawl space or up the wall to the attic. CSST from the manifold to the top plate or bottom plate. Black pipe in the wall and stubbed out of the sheetrock to within about a foot of the applicance. CSST from the stub to more black pipe with a sediment/drip leg. Basically all the black pipe is standard length pipe so no cutting or threading.

The house is question was 11 months old. Water heater and attic furnace had CSST last foot. Heat pack had all black pipe.

Western NC is category 3 so has to meet siesmic stuff but that is basically Winston Salem and points West.

I was in Fuquay Monday. Fuquay, the best of all the Varinas.
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
  #9 (permalink)  
Old 02-13-2008, 08:12 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,644
Re: CSST required at gas appliances
Quote:
Originally Posted by Bruce Ramsey View Post
Western NC is category 3 ...

"category 3"????

Seismic is categorized as (least to worst): A, B, C, D0, D1, D2, E.

Western NC is shown as being mostly C, from which detached one- and two-family is exempt. See Figure R301.2(2) continued (on page 31 in the CD IRC).

R301.2.2 Seismic provisions.
The seismic provisions of this code shall apply to buildings constructed in Seismic Design Categories C, D
0, D1 and D2, as determined in accordance with this section. Buildings in Seismic Design Category E shall be designed in accordance with the International Building Code, except when the seismic design category is reclassified to a lower seismic design category in accordance with Section R301.2.2.1.

- Exception:
Detached one- and two-family dwellings located in Seismic Design Category C are exempt from the seismic requirements of this code.

__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #10 (permalink)  
Old 02-14-2008, 07:40 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 145
Re: CSST required at gas applicances
C, 3 What's the difference.

I guess the exemption is the real answer. Not an issue since most my inspections are in category B teritory.

Thanks for the redirect.
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
  #11 (permalink)  
Old 02-15-2008, 06:36 AM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,644
Re: CSST required at gas appliances
Quote:
Originally Posted by Bruce Ramsey View Post
C, 3 What's the difference. .
Or maybe dyslexic and 3 was really E? BIG difference there.

__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
CSST Mike Parks Safety Recalls and Notices 24 05-08-2008 06:45 AM
csst and lightning Victor DaGraca Plumbing System: Home Inspection and Commercial Inspection 5 10-26-2007 01:55 PM
csst wayne soper Plumbing System: Home Inspection and Commercial Inspection 4 07-09-2007 06:14 PM
Sweeping Required? Dale W. Feb Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 12 06-12-2007 05:01 PM
CSST bonding Thom Walker Plumbing System: Home Inspection and Commercial Inspection 7 05-09-2007 09:29 PM


All times are GMT -7. The time now is 11:34 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger