You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 04-26-2007, 07:05 PM
Gregg Austensen Gregg Austensen is offline
Member
 
Join Date: Mar 2007
Location: Columbus, GA
Posts: 26
Furnace vent installation
Is the angle and horizontal run incorrect?
Attached Images
File Type: jpg P4260079.JPG (112.2 KB, 50 views)
Reply With Quote
  #2 (permalink)  
Old 04-26-2007, 07:22 PM
Jerry Peck Jerry Peck is online now
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,629
Re: Furnace vent installation
Looks like it runs downhill to me, and it should slope uphill.

Also looks to run too far horizontally for the total height run.

Looks kinda like someone wanted it to run to the back side of the roof (so they did not have to see it when they drove in) when it should have run straight up.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
EastWestData (www.EastWestData.com )
Reply With Quote
  #3 (permalink)  
Old 04-26-2007, 07:37 PM
Gregg Austensen Gregg Austensen is offline
Member
 
Join Date: Mar 2007
Location: Columbus, GA
Posts: 26
Re: Furnace vent installation
Jerry,
The furnace was a replacement and they ran it to the existing hole in the roof. Nobody likes to make work do they. You can't see it in the picture but the end of the vent discharges below the roofline in the attic. Does it matter if there is a blower assist?
Reply With Quote
  #4 (permalink)  
Old 07-16-2008, 07:51 PM
Richard Drennan
 
Posts: n/a
Re: Furnace vent installation
60% plus of the vent pipe should be verticle for any application and should NEVER slope downhill even with an inducer. It looks as though they were just lazy.
Reply With Quote
Home inspection
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Exterior Installation of Gas Flex Line Nick Ostrowski Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 14 04-28-2007 02:38 PM
Single Wall Window Installation Mike Drorbaugh Building Envelope: Home Inspection and Commercial Inspection 12 04-25-2007 06:03 PM
Rheem furnace age Paul Kondzich Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 5 04-22-2007 11:23 PM
Condensate leak at furnace exhaust Paul Kondzich Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 2 04-15-2007 09:08 AM
Furnace vent Jeff Eastman Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 3 04-14-2007 07:28 PM


All times are GMT -7. The time now is 12:34 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger