InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-07-2008, 02:53 PM
Ken Larson Ken Larson is offline
Member
 
Join Date: Mar 2007
Location: Austin, TX
Posts: 58
HVAC New Installation
Other than sloppy workmanship is there any reason why a HVAC installer would just leave the zoning panel and transformer just laying on top the attic equipment like this? I've probably done over 3000 inspections and never seen crap like this on a brand new install. I don't know of any building codes that would prohibit it other than the general manufacturers installation manual.
Attached Images
File Type: jpg IMG_2399.JPG (53.7 KB, 159 views)
__________________
Austin Structural Inspections
email: larson@austinstructural.com
web: www.austinstructural.com
Reply With Quote
IC Home Inspection Report Writing
  #2 (permalink)  
Old 07-07-2008, 03:14 PM
Rick Cantrell Rick Cantrell is offline
Member
 
Join Date: Mar 2007
Location: Columbus GA
Posts: 777
Re: HVAC New Installation
If the transformer has live wires connected to it then it should be mounted in an enclosure.
As for the zoning panel ? Don't know. Maybe the instructions say where/ how and if, it should be mounted to anything.
PS
Alarm equipment should not be located in the attic because the temperature can exceed manufactures limits.
This may apply the other electronic equipment as well.
__________________
Rick Cantrell
Columbus GA
Reply With Quote
  #3 (permalink)  
Old 07-07-2008, 04:54 PM
DavidR's Avatar
DavidR DavidR is offline
Member
 
Join Date: May 2007
Location: Frankfort, KY
Posts: 281
Re: HVAC New Installation
If you can get your hands on the install instructions for that zone panel I would bet it isn't approved for installation in an attic like that.

Transformer should have been mounted in the equipment with the line voltage wiring NOT exposed like it is.

I've seen a lot of bad zone systems but yours has to take the prize Ken.
__________________
Measured Performance more than just a buzzword
Reply With Quote
  #4 (permalink)  
Old 07-07-2008, 05:06 PM
Markus Keller Markus Keller is offline
Member
 
Join Date: Feb 2008
Location: Chicago IL
Posts: 778
Re: HVAC New Installation
- Transformer should be screwed on inside the cabinet with the rest of the controls.
- We don't allow romex at all, so I'm guessing nonetheless it shouldn't be hanging in the air like that.
- Is that a yellow flex gas hose to the unit instead of black pipe?
- panel should be mounted somewhere
__________________
Accurate Inspections & Consulting, Inc.
773/844-4AIC
"The Code is not a ceiling to reach but a floor to work up from"
Reply With Quote
  #5 (permalink)  
Old 07-07-2008, 10:00 PM
Randy Clayton Randy Clayton is offline
Member
 
Join Date: Apr 2008
Location: Katy Texas
Posts: 105
Re: HVAC New Installation
Just plain poor quality install.
Reply With Quote
  #6 (permalink)  
Old 09-25-2008, 02:14 PM
Dan Hagman's Avatar
Dan Hagman Dan Hagman is offline
Member
 
Join Date: Aug 2008
Location: Altoona, Iowa
Posts: 49
Re: HVAC New Installation
Zone Control panel needs to be mounted!
This is a 40 VA transformer and the line voltage wires (BLK & White) go inside of the unit.The unused orange wire appears to be for a 240 Volt primary use. The transformer should have been mounted and secured with the line voltage wires in a box. The control wires can be outside the unit. The transformer can also be mounted outside the unit so long as it is secured. They used the wrong style of transformer, They should have used a box mount 40 VA transformer and installed another box on top of this unit. Just poor workmanship !

Dan Hagman
Hagman Heating and Cooling (Rheem Dealer)
Altoona, Iowa
NOW
ProSite Home Inspections
Reply With Quote
  #7 (permalink)  
Old 09-26-2008, 02:51 PM
Dave Hahn Dave Hahn is offline
Member
 
Join Date: Mar 2007
Location: Charlotte, NC
Posts: 69
Re: HVAC New Installation
Broke for lunch.
Forgot to come back....
Reply With Quote
IC Home Inspection Report Writing
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
HVAC freeze up David Edens Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 2 02-28-2008 05:40 PM
HVAC Dominic Caronna Roofing System: Home Inspection and Commercial Inspection 2 02-26-2008 09:08 AM
HVAC return air William Mize Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 2 08-10-2007 03:24 PM
HVAC Help Please Matt Hawley Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 17 07-27-2007 12:17 PM
HVAC disconnect M Kelekci Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 4 07-06-2007 09:04 PM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 09:02 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger