You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 07-19-2008, 04:02 PM
Alton Darty Alton Darty is offline
Member
 
Join Date: Dec 2007
Location: Osceola, AR
Posts: 73
Ack-O-Matic Boiler Age
Ok, don't know a lot about boilers, we don't have many of them around anymore. Anyone got a clue on the age of this one? Where can I access an age chart or is there even one available?

Alton Darty
ATN Services
Osceola, AR
Attached Images
File Type: jpg DSCF3208a.jpg (103.6 KB, 44 views)
Reply With Quote
  #2 (permalink)  
Old 07-19-2008, 05:13 PM
John Arnold John Arnold is online now
Member
 
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,200
Re: Ack-O-Matic Boiler Age
Ack-O-Matic?! What a great name!
It sounds like something from Bloom County.
Any photos of the whole thing?
Attached Images
File Type: jpg bill.jpg (17.3 KB, 6 views)
Reply With Quote
  #3 (permalink)  
Old 07-19-2008, 05:24 PM
John Arnold John Arnold is online now
Member
 
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,200
Re: Ack-O-Matic Boiler Age
For what it's worth, take a look at this:
Any idea on how old............ - Heating and Air - BBS - BobVila.com

And in case you didn't click on "pretty old", this is the text that goes along with it:
"Most ack-o-matic boilers were installed and made in the early 60's. They are no longer produced, and if they are in need of work. I suggest you call around, if they have never heard of the brand, then they shouldn't be allowed to touch it. If you have any questions, please feel free to e-mail me at nikki@blueskyplumbing.com "
Reply With Quote
  #4 (permalink)  
Old 07-19-2008, 05:39 PM
Alton Darty Alton Darty is offline
Member
 
Join Date: Dec 2007
Location: Osceola, AR
Posts: 73
Re: Ack-O-Matic Boiler Age
Sorry no pics of the entire unit, very cramped space, and I didn't have my wide angle lens with me. I think that I may have access to another unit that should be about the same age. I may even have a chance to look at this one more closely. I asked my client if he would give me a call when he started some of the projects on the house. From what I gathered the heating system is priority #1. If I get to examine this beast outside it's normal habitat I will get some pics to share. In the meantime i may try to post some of the other pics from this property.
Alton Darty
ATN Services
Osceola, AR
Attached Images
File Type: jpg drafthood.jpg (31.6 KB, 25 views)
Reply With Quote
  #5 (permalink)  
Old 07-19-2008, 05:43 PM
John Arnold John Arnold is online now
Member
 
Join Date: Mar 2007
Location: Philadelphia PA
Posts: 1,200
Re: Ack-O-Matic Boiler Age
How old was the house? Early '60s by any chance?
Reply With Quote
  #6 (permalink)  
Old 07-19-2008, 06:20 PM
Alton Darty Alton Darty is offline
Member
 
Join Date: Dec 2007
Location: Osceola, AR
Posts: 73
Re: Ack-O-Matic Boiler Age
Hard to say, maybe '60 at the latest, I would lean more toward something earlier. The area this one is in was built up in the '30s to early '50s. Can't get much info on it to be sure. From the records that the buyer has access to also lean toward something a little earlier, tax assesment from the early '40's shows the property as a residence, but the names don't agree with the available info, but then there could have been a fire or something along that line. The configuration of the small area that the boiler and water heater are in lead me to think that there was possibly a coal fired unit here earlier. It's my understanding that coal fired boilers were the norm here until about the late 50's early 60's. I do remember one being in use at my school when I was but a wee lad.
Alton Darty
ATN Services
Osceola, AR
Reply With Quote
  #7 (permalink)  
Old 07-20-2008, 06:04 AM
neal lewis neal lewis is offline
Member
 
Join Date: Mar 2007
Location: Ridgewood, NJ
Posts: 82
Re: Ack-O-Matic Boiler Age
I would just report the boiler is at least 40 years old, etc. I don't see the need to report on an exact date of older equipment. There could be dates on the expansion tank, relief valve, gas valve, owner's manual, etc.

Regarding the plumber's assessment that if you've never heard of the brand, you shouldn't touch it. It looks like a common cast iron boiler. The parts should be compatible with what's available today and I doubt there's anything complicated about it.

FWIW, the age of the house should be obvious to within ten years or so, just by type of building materials, fixtures, styles of windows, doors, casing, etc.
Reply With Quote
  #8 (permalink)  
Old 07-20-2008, 07:18 AM
Alton Darty Alton Darty is offline
Member
 
Join Date: Dec 2007
Location: Osceola, AR
Posts: 73
Re: Ack-O-Matic Boiler Age
Quote:
Originally Posted by neal lewis View Post
I would just report the boiler is at least 40 years old, etc. I don't see the need to report on an exact date of older equipment. There could be dates on the expansion tank, relief valve, gas valve, owner's manual, etc.

Regarding the plumber's assessment that if you've never heard of the brand, you shouldn't touch it. It looks like a common cast iron boiler. The parts should be compatible with what's available today and I doubt there's anything complicated about it.

FWIW, the age of the house should be obvious to within ten years or so, just by type of building materials, fixtures, styles of windows, doors, casing, etc.
Report is done and e-mailed. Unit was reported as being 40+ years old and having exceeded its useful lifespan (that decision was after a call to a local heating contractor who informed me that the unit was at least 40 years old and that he would not attempt anything but a replacement if there were any issues with the unit).
I am asking for my own benefit, when I run across something out of the ordinary I try to become informed just in case I see the same again.
As far as dates on gas valves, expansion tanks, etc. the range was from 1953 to 1982, but the gas valve with the 1953 date did not appear original to the unit.
As far as materials, fixtures, and styles I am still going with early to mid '50s as my best guess on age range. Although the glass in many of the windows is the older "wavy" glass. There are a lot of discrepancies that I see in materials and construction techniques as far as age is concerned. I originally thought that the home may have had several additions since it's original construction, however the attic and the crawl don't support that either.
Alton Darty
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
bulldog push matic Jerome W. Young Electrical Systems: Home Inspection and Commercial Inspection 8 05-10-2008 08:56 AM
Boiler Delta Jim Robinson Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 2 03-13-2008 12:58 PM
boiler age? John Arnold Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 10 02-20-2008 06:33 PM
Kitchen boiler David Banks Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 5 12-30-2007 07:51 PM
Viallant Boiler age Brian E Kelly Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 3 10-14-2007 11:23 AM


All times are GMT -7. The time now is 01:04 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger