You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

09-04-2008, 08:48 PM
|
 |
Member
|
|
Join Date: May 2008
Location: Ontario
Posts: 18
|
|
|
furnace motor buzz
Tempstar High Efficiency furnace had a hum/buzz typical of a motor trying to start: With the panel removed, and depressing the cut-out switch the fan motor (or something on the electronic panel attached to it) made this sound. The thermostat was set to OFF (set to engage neither furnace nor A/C), and the fan setting on the thermostat at Auto. I didn't think the fan would be trying to start under this scenario.
When I changed the fan setting at thermostat to ON the fan would spin - after a brief delay (3-4 seconds) but with the same noise.
The house is vacant, gas turned off, and only the AC has been used in the last several months.
The fan is dirty - lots of vibration when it did run (7 years old).
The prospective buyer is having a tech in tomorrow, but in the meantime, I'm curious. Any ideas?
|
|

09-04-2008, 08:55 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,578
|
|
|
Re: furnace motor buzz
Sounds like a transformer, not the motor.
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
|
|

09-05-2008, 01:36 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: New Mexico
Posts: 341
|
|
|
Re: furnace motor buzz
Transformer. I just minimized the buzzing on my rental property furnace, and it was doing exactly the same thing. I loosened the screws a little bit and isolated the transformer from the metal bracket with a piece of paper. I can still hear it, but it's much quieter.
__________________
Jim Robinson
New Mexico, USA
|
|

09-05-2008, 01:44 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,395
|
|
|
Re: furnace motor buzz
Furnace motor buzz?
Good Lord, these kids will try anything nowadays for that buzz.
We used to slam a few beers for a buzz, but I get thats not exciting anymore. 
|
|

09-09-2008, 03:30 PM
|
 |
Member
|
|
Join Date: Aug 2008
Location: Altoona, Iowa
Posts: 39
|
|
|
Re: furnace motor buzz
Jim & Jim are correct, it has a 40 VA transformer making the noise. They do this all the time. It's in the way it is mounted. I have seen people hang them so they don't touch anything. Poor way of doing it. All transformers buzz.
Dan
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
All times are GMT -7. The time now is 08:20 AM.
| | |
|

All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by
RedTyger