    I can't find my notching/boring cheat sheet. Can someone tell me if this is too much?

    Nothing like making things harder than they have to be. This is a dryer vent!

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Crawl Space Creeper

  2. #2
    Join Date
    Aug 2007
    Location
    Memphis TN.
    Posts
    4,311

    Default Re: Excess notch?

    This appears over 1/3 of the depth so yes it's over the allowed depth .

    It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
    Billy J. Stephens HI Service Memphis TN.

  3. #3
    Join Date
    Mar 2007
    Location
    Spring City/Surrounding Philadelphia area
    Posts
    3,509

    Default Re: Excess notch?

    I thought notching limitation was no more than 1/6th the depth. Either way, that installer went well beyond the limit.

    "It takes a big man to cry. It takes an even bigger man to laugh at that man". - Jack Handey

  4. #4
    Join Date
    Aug 2007
    Location
    Memphis TN.
    Posts
    4,311

    Default Re: Excess notch?

    Quote Originally Posted by Nick Ostrowski View Post
    I thought notching limitation was no more than 1/6th the depth. Either way, that installer went well beyond the limit.
    Whoops Correct 1/6th depth, 1/3 length of the depth.

    Attached Files Attached Files
    It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
    Billy J. Stephens HI Service Memphis TN.

  5. #5
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Excess notch?

    That's not a 'notch', that's where they went to lunch and just forgot to finish cutting it when they got back from lunch.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  6. #6
    Join Date
    Mar 2007
    Location
    Oregon
    Posts
    2,365

    Default Re: Excess notch?

    I should have stressed my sarcasm more in the OP..... 1/3, 1/6, 7/8 .... whatever..... that one is waaaaay "over done". It's just so funny that it's a dryer vent. When it's a drain/waste line it's of course still wrong but at least I can understand it since the installer was trying to maintain a certain line.

    A dryer vent? That's just plain ridiculous.