Thread: Did I do this right???
-
03-13-2009, 08:08 AM #1
Did I do this right???
HI All,
This is my 3rd calander year in the business and from time to time I have to ask Hmmmmm? I don't know what I don't know.
Please let me know your thoughts on how this should be handled.
I found this egress window the other day in a living area NOT a bedroom. There were 2 seperate sliding windows with a opening of only 13"...Height was less than 36" I cant remember now. It's my understanding that the min opening for egress is @5 sq ft. with a min width of 20". Along with the small opening, there was not escape ladder or cover over the egress. The house was built in 1984. I wrote in them up as a fire hazard stating that the windows must be 5sq ft or larger and a ladder/grate cover must be installed.
Any suggestions?
Thanks !!!
Jake
-
03-13-2009, 08:14 AM #2
Re: Did I do this right???
Shouldn't have written it up. Only bedroom windows are required to be of a minimum size.
Oh....Welcome to the board!
Last edited by Wayne Carlisle; 03-13-2009 at 08:15 AM. Reason: Welcomed Jake
-
03-13-2009, 08:34 AM #3
Re: Did I do this right???
Thanks.
But without a ladder it's still a fire hazard right?
IRC 310.1 reads "All basements with habitable space require escape and rescue opening. Does the size of the window not apply unless its a bedroom?
-
03-13-2009, 08:37 AM #4
Re: Did I do this right???
Basements are a different story!
Does it have a door to the outside?
-
03-13-2009, 09:45 AM #5
Re: Did I do this right???
Other than the 2 tiny windows, the stairs are the only way out. No door.