You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

01-27-2008, 12:52 PM
|
|
Member
|
|
Join Date: Mar 2007
Posts: 2
|
|
|
Crawl space moisture barrier
What is the code for moisture barriers in crawl spaces? Are they required and if so, anybody have a code number.
|
|

01-27-2008, 02:30 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Longwood, FL
Posts: 302
|
|
|
Re: Crawl space moisture barrier
Hello,
Where are you located and what Codes are used in your area?
|
|

01-27-2008, 02:31 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Woodland Park, CO.
Posts: 170
|
|
|
Re: Crawl space moisture barrier
Is the crawl space vented, etc. etc. etc.
|
|

01-30-2008, 12:14 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: New Hampshire
Posts: 29
|
|
|
Re: Crawl space moisture barrier
Unless you have to back up your comments because a seller is complaining about the suggestion, I don't see why Code should be brought up.
I comment in all reports that they should have a vapor barrier on a dirt floor. It goes under the "Suggested idea" level in the report. Something they should consider doing to keep the house in good condition.
Has this become and issue with the Real Estate transaction?
|
|

01-30-2008, 05:59 PM
|
|
Member
|
|
Join Date: Mar 2007
Posts: 2
|
|
|
Re: Crawl space moisture barrier
I'm an expert witness in a trial coming up and want to be prepared to back up the need for 6mm moisture barrier in crawl spaces. I'm trying to find a code to quote.
|
|

01-30-2008, 06:06 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: San Mateo, CA
Posts: 1,103
|
|
|
Re: Crawl space moisture barrier
Erwin
If you want help here first answer the questions asked. Nobody can help without some details such as what was asked for.
|
|

01-30-2008, 08:32 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,635
|
|
|
Re: Crawl space moisture barrier
Originally Posted by Dom D'Agostino
Where are you located and what Codes are used in your area?
Erwin,
What - where?
(Or, should I say 'Where - what?')
You have not answered Dom's questions and NO answers can be given without the information.
Guesses can be made, but you can do that.
|
|

01-31-2008, 05:46 AM
|
|
Senior Member
|
|
Join Date: Mar 2007
Location: Nowhere, USA
Posts: 828
|
|
|
Re: Crawl space moisture barrier
Originally Posted by Erwin Cox
What is the code for moisture barriers in crawl spaces? Are they required and if so, anybody have a code number.
Erwin:
You really aren't forthcoming with much information, but here's my take on it. If you are being called as an expert you will want as much authority on your side as you can muster. The model building code is one good thing to have in your camp in theses circumstances. Without that reference you will be relying solely on your opinion, "customary building practices in your area", of the AHJ's (usually) uneducated guess at what's correct.
IRC N 1102.1.7 states in part "The exposed earth in all crawl space foundations shall be covered with a continuous vapor retarder having a maximum permeance rating of 1.0 perm [(57 mg)/(s · m2 · Pa)], when tested in accordance with ASTM E 96."
Go to: Plone —
Look up the info based upon the area of the country you're in. Joe Lstiburek, Ph.D. and Nathan Yost, M.D. have good crawl space info on this site.
Also try IBACOS: Integrated Building and Construction Solutions, Forest Products Laboratory -- Forest Service -- USDA, U.S. DOE Energy Efficiency and Renewable Energy (EERE) Home Page, ad infinitum.
Don't go to court half-cocked.
Aaron 
|
|

01-31-2008, 07:14 AM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,395
|
|
|
Re: Crawl space moisture barrier
Aaron,
How many crawlspaces have you seen that have a vapor barrier in our area?
I've maybe seen 10 in the last 20 years.
Just not common in this area are they?
rick
|
|

01-31-2008, 07:34 AM
|
|
Senior Member
|
|
Join Date: Mar 2007
Location: Nowhere, USA
Posts: 828
|
|
|
Re: Crawl space moisture barrier
Rick:
No, they aren't common here. Even when I see a vapor barrier, it's 6-mil polyethylene that's been seemingly applied with a scattergun. I always write up crawl spaces as in need of a vapor barrier and recommend the upgrade from 6-mil polyethylene to 20-mil EPDM or PVC pond liner with solvent-welded lap joints. Those are relatively permanent and can be traversed by repairmen and inspectors without damage.
The few builders here that still construct pier and beam foundations with crawl spaces are still living in the 50's technologically speaking. The last I saw was a new 6-million dollar box in Highland Park. The builder put down 6-mil polyethylene and then covered it with crushed rock (to properly perforate the plastic, I assume). In addition he added a high-end sump pump at the high end of the sloped crawl grade and humidistat-controlled fans that were installed backward (blowing into the crawl space - useless except for pressurizing the crawl and send the moisture through the wooden floors).
When I told him he had significant mold growth on the undercarriage, he scoffed. I got him an extra pair of coveralls from the van and invited him to crawl on that damned crushed stone to have a look. Served his knees just right.
Aaron 
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Crawl Space Foundation |
Erol Kartal |
Sub-Structure: Home Inspection and Commercial Inspection |
6 |
10-15-2007 09:38 AM |
| Crawl space questions? |
M Kelekci |
Structural Components: Home Inspection and Commercial Inspection |
25 |
08-02-2007 06:49 AM |
| Combustion Air in Crawl Space |
David Samloff |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
18 |
07-27-2007 08:44 PM |
| Vapor barrier tacked to crawl decking |
Matt Fellman |
Sub-Structure: Home Inspection and Commercial Inspection |
9 |
07-15-2007 09:01 PM |
| Enclosed Crawl space ? |
Jim Holl |
Sub-Structure: Home Inspection and Commercial Inspection |
4 |
04-12-2007 11:36 PM |
All times are GMT -7. The time now is 07:30 PM.
| | |
|