10-11-2008, 01:44 PM #1
TPR discharge pipe
Tell me this is wrong. I'm refering to code check (IRC 2803.6.1 and UPC 608.5). AS you can see this was an approved installation.
Rich
Similar Threads:
-
10-11-2008, 01:56 PM #2
Re: TPR discharge pipe
" THIS IS WRONG" cannot be facing up. Must be able to see termination also. Could you?
-
10-11-2008, 05:07 PM #3
Re: TPR discharge pipe
That NM cable is wrong too.
Looks like that is in a closet, in which case it would also require a disconnect to disconnect the water heater from its supply. (There is an exception for the disconnect, but with what is shown in that photo, I doubt it applies.)
Is that discharging into PVC in the corner behind the water heater? If so, that is not allowed either.
-
10-13-2008, 05:50 PM #4
Re: TPR discharge pipe
Wow. That's a whole lot of effort to do something completely wrong.
The icing on the cake, though, are the two APPROVAL stickers on the side of that thing.