    The plumber on a new construction told me that there was no height requirement for the AAV on the kitchen island. Just accessibility. I believe its 4 in. above the fixture drain and/or 4 in. above the horizontal branch drain. Right or wrong?

    Similar Threads:
    Inspection Referral

  2. #2
    Michael Garrity's Avatar
    Michael Garrity Guest

    Default Re: AAV code

    You are right


  3. #3
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: AAV code

    Quote Originally Posted by Dylan Shoop View Post
    The plumber on a new construction told me that there was no height requirement for the AAV on the kitchen island. Just accessibility. I believe its 4 in. above the fixture drain and/or 4 in. above the horizontal branch drain. Right or wrong?
    4" above the weir of the trap.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  4. #4
    Richard Moore's Avatar
    Richard Moore Guest

    Default Re: AAV code

    Just to clarify...it's a minimum of 4". More is OK.


  5. #5
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: AAV code

    Quote Originally Posted by Richard Moore View Post
    Just to clarify...it's a minimum of 4". More is OK.
    Correct.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com