    Ok this guy removed a pump for a well system. Here is what is left. Are these unions acceptable. I laugh when I say a funnel duct taped to this to catch water from the leaky union.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Member Benefits1

  2. #2
    Join Date
    Mar 2007
    Location
    Spring Hill (Nashville), TN
    Posts
    5,851

    Default Re: Plumbers need your help

    That looks like part of a rear end to a 69 VW Micro Bus!

    Scott Patterson, ACI
    Spring Hill, TN
    www.traceinspections.com

  3. #3
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: Plumbers need your help

    LOL. I wish i had a picture of the funnel the guy set up to catch water leaking from the line. It was then directed to the flowers. LOl


  4. #4
    Join Date
    Feb 2008
    Location
    Caledon, Ontario
    Posts
    4,982

    Default Re: Plumbers need your help

    Looks like a dogs breakfast!


  5. #5
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: Plumbers need your help

    Ok, but what about all the crazy connections. Galv to copper, Galv to PVC and whatever the hell else is there.


  6. #6
    Join Date
    Nov 2007
    Location
    Chicago
    Posts
    548

    Default Re: Plumbers need your help

    Unions look fine, but the one nipple from the brass check valve to the union needs to be replaced. Personaly i would tear it all out and get rid of the dead end tees. and pipe it all in copper to the plastic. They make real nice sweat by sweat unions.


  7. #7
    Join Date
    Apr 2007
    Location
    state of jefferson
    Posts
    522

    Default Re: Plumbers need your help

    dead ends etc were probably used to accomodate the pressure guage and switch, softener tanks etc. may want them there for future use?


  8. #8
    Join Date
    Nov 2007
    Location
    Chicago
    Posts
    548

    Default Re: Plumbers need your help

    Quote Originally Posted by brian schmitt View Post
    dead ends etc were probably used to accomodate the pressure guage and switch, softener tanks etc. may want them there for future use?
    Future leaks maybe. If there is no legit use for them get rid of them. They are a breading ground for for bad things. Many times I took a plug out of a tee and seen a slime that was growing in the unused branch. Like I said Repipe it all with copper to the plastic. Right at the plastic I put a threaded valve, like they got now, a brass nipple then the threaded check valve then another brass nipple, with an IPS X sweat union preferably brass by copper, no need for a dielectric since we are dealing with all brass fittings and copper pipe. The finish off with the copper hookup.

    If the well pump is gone and he is on city water you can get rid of the check valve. But since there is a check valve, is there an expansion tank on the water heater?


  9. #9
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Plumbers need your help

    Quote Originally Posted by mathew stouffer View Post
    Ok, but what about all the crazy connections. Galv to copper, Galv to PVC and whatever the hell else is there.
    Starting at the PVC:
    - looks like an PVC adapter and not a PVC-Brass transition was used to the brass water shut off valve
    - brass valve to galvanized tee is okay
    - there should not be any dead ends
    - galvanized tee to brass check valve is okay
    - brass check valve to galvanized union is okay (well, except for the leaking stuff)
    - galvanized to copper looks to be through a dielectric fitting, cannot tell for sure from the angle of the photo

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  10. #10
    Join Date
    Mar 2007
    Location
    Near Philly, Pa.
    Posts
    1,682

    Cool Re: Plumbers need your help

    There appears to be pipe dope on the face of that ground union. How is all this supported?

    Looks the same way houses are built--modified over time by various and dubious means.

    Keep the fire in the fireplace.

  11. #11
    Join Date
    Mar 2007
    Location
    South-West Michigan
    Posts
    469

    Post Re: Plumbers need your help

    How about a hand-operated shut off? Unless there is a Crescent wrench stored nearby, of course.

    Randall Aldering GHI BAOM MSM
    Housesmithe Inspection
    www.housesmithe.com

  12. #12
    mathew stouffer's Avatar
    mathew stouffer Guest

    Default Re: Plumbers need your help

    I found ou the guy buying the place is a plumber of 20 years. We had a good laugh.


  13. #13
    Randy Cooper's Avatar
    Randy Cooper Guest

    Default Re: Plumbers need your help

    They allow PVC in Utah? Not in California. A dielectric union is required between dissimilar metals here; between the copper and galvanized piping.


  14. #14
    Joshua Hardesty's Avatar
    Joshua Hardesty Guest

    Default Re: Plumbers need your help

    If you look closely enough at the Copper -> Galv. connection, it looks like it's sweated into a brass piece. I'd take a closer look at that fitting, though. I've seen a lot of unions that look like that, but never one that just screws onto a nipple like that. Like it's missing half of the union. (But just because I've never seen it...)

    Also if that pump plans on staying out for a long time, I'd yank out anything unnecessary. Galvanized never looks pretty after a few years.