    Default Re: Seen this yet?

    So first home today. Just what is called out in the suit. Any of you guys have any other info on this. They are saying lightning strikes blow out the gas lines.

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images

  3. #3
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Seen this yet?

    Not if they are properly bonded to ground.

    The problem, as I understand it, is that, while inspectors made the installers bond 'metal gas piping' (meaning rigid pipe) to ground, they forgot to (in some areas) make sure that the installers bond 'metal gas piping' (meaning CSST) to ground.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com