07-14-2007, 05:42 AM #2
Re: Thank the lord......
They have some serious venting issues. Look at the disoloration. Also, where is the draft hood connector? I don't even see any screws.
The manual should remain with the unit. If it is damaged then state it should be replaced.
Keep the fire in the fireplace.
-
07-14-2007, 08:34 AM #3
Re: Thank the lord......
In addition to what Bob H. said, that flexible copper line 'is reduced in size' and should not be used for the T&P discharge drain line.
If you put photos in your report, that would be a good one to put in there.
Bob H., question for you: Are those nylon/Teflon/whatever-type-plastic pieces in those flexible line connections allowed that close to the draft hood/vent? I've always been curious about that.