Thread: AAV below the disposal drain
-
02-22-2012, 03:04 PM #1
AAV below the disposal drain
Is this an issue that needs correcting?
I think the AAV should be higher than the disposal drain exit. Someone else has a differing opinion.
Similar Threads:We know why you fly: because the bus is too expensive and the railroad has a dress code...
www.atozinspector.com
-
02-22-2012, 03:29 PM #2
Re: AAV below the disposal drain
Oatey AAV height info:
Must be installed no less than 4” above the center line of the highest trap arm served and not within 2 pipe diameters of a trap weir.
http://www.google.com/url?sa=t&rct=j...crZeKQ&cad=rja
-
02-22-2012, 04:02 PM #3
Re: AAV below the disposal drain
Thanks Dom,
I'll be keeping the pdf source cited.