    Default Circulator Attached to Direct Vent Wtr Htr

    50 gallon, direct vent, natural gas water heater in garage on 18 inch stand. There is a pipe connected to the water heater about a foot above the burner into the side of the water heater. Installed in the pipe is a Circulator Taco Cartridge that has a power cord. Power cord is not plugged in. No solar water heater panels were observed.

    Not sure what a Circulator Taco Cartridge is. Any guesses?

    Someone was talking to me on the phone while I was taking the pictures distracting me and I thought I got enough. Now I am not sure.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Member Benefits1
    "The Code is not a peak to reach but a foundation to build from."

  2. #2
    Join Date
    Oct 2003
    Location
    Rockwall Texas
    Posts
    4,521

    Default Re: Circulator Attached to Direct Vent Wtr Htr

    Bruce,

    It looks like it is a re-circulatory pump. Most I see are unplugged also.

    rick


  3. #3
    Join Date
    Aug 2007
    Location
    Memphis TN.
    Posts
    4,311

    Default Re: Circulator Attached to Direct Vent Wtr Htr

    Bruce,

    I'm not sure about the Taco.

    But as you have posted the pictures,

    The flue looks to Flat needs (1/4 " per foot up slope.)

    The pipe insulation can not be in contact with the flue as it is combustible.


    Here you Go!

    www.nextag.com/taco-cartridge-circulator/search-html

    Last edited by Billy Stephens; 12-12-2007 at 05:24 PM. Reason: link added
    It Might have Choked Artie But it ain't gone'a choke Stymie! Our Gang " The Pooch " (1932)
    Billy J. Stephens HI Service Memphis TN.

  4. #4
    Join Date
    Mar 2007
    Location
    Myrtle Beach, South Carolina
    Posts
    341

    Default Re: Circulator Attached to Direct Vent Wtr Htr

    Critical Home Inspection Services
    www.Home2Spec.com

  5. #5
    Join Date
    Mar 2007
    Location
    Atlanta, Georgia
    Posts
    1,088

    Default Re: Circulator Attached to Direct Vent Wtr Htr

    Thanks to one and all. I forgot to check google myself. Silly me.

    I just assumed it to be some home inspector thing I didn't know about.

    This house had a number of "upgrades". Whoever lived there was a very busy person. They had a cat door through the kitchen wall that lead into a bench seat on the deck. The bench seat was enclosed on all sides. Inside the bench seat was a ramp down to grade. Under the deck was enclosed in wire mesh. Kitty could go outside but be still be contained at the same time. There was an opening in the mesh that led to another mesh box. It was the litter box. Under the deck was covered with gravel.

    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    "The Code is not a peak to reach but a foundation to build from."

  6. #6
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Circulator Attached to Direct Vent Wtr Htr

    Recirculating pump, does not do any good if not plugged in.

    Recirculating pump wired with extension cord with end cut off - NOT GOOD. Needs to have a receptacle outlet down within reach of a standard appliance cord, of the cord and plug which came with that if it came with a cord and plug. Also, a proper (and properly installed) cord strain relief clamp is needed at the pump.

    Nothing is holding that T&P CPVC (looks like CPVC) discharge line in place, that thing could move around under emergency discharge conditions.

    Are you sure that is direct vent? You mean fan assisted? Looks like a blower fan on top.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  7. #7
    Join Date
    Oct 2003
    Location
    Rockwall Texas
    Posts
    4,521

    Default Re: Circulator Attached to Direct Vent Wtr Htr

    Bruce,

    That is one pampered cat.

    Reminds me though of a T-shirt I saw this guy wearing the other day.

    It said, "I Love Cats.. I just can't eat a whole one by myself"

    The ones I like is the people who have a complete homemade HVAC system set up for the exterior dog house.