    Default Goofy P-trap

    So, this looks goofy, but I can't tell if it's wrong. Can someone comment?

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    Inspection Referral
    Department of Redundancy Department
    Supreme Emperor of Hyperbole
    http://www.FullCircleInspect.com/

  2. #2
    Join Date
    Mar 2007
    Location
    Fletcher, NC
    Posts
    28,042

    Default Re: Goofy P-trap

    It is effectively an S- trap.

    After the P-trap, it should slope just very slightly to the vent.

    The easy solution, if there is space (I can't tell from the photo), would be to use a tailpiece extension to lower the trap to where the wall bend piece at the outlet of the trap goes straight into that lower piece (The trap arm).

    But it is quite likely that the trap arm is to close to the bottom of the cabinet for the trap to have enough space (height).

    Trying to 'measure' using what's shown in the photo causes me to think there is enough space for the trap to be lowered and work ... but maybe not.

    Jerry Peck
    Construction/Litigation/Code Consultant - Retired
    www.AskCodeMan.com

  3. #3
    Join Date
    Mar 2007
    Location
    Santa Rosa, CA
    Posts
    3,154

    Default Re: Goofy P-trap

    Hi Jerry,

    Thank you for the response.

    Yes, there is room for proper p-trap installation. I feel silly having asked this question. I was really beat yesterday and kept thinking "that can't be right, but why?" So, I took the pic and attempted to write the report. When my eyes closed for the 4th time, I decided to pack it in. Now that I have had a good night's sleep, it (and several other thing from that inspection) are much clearer.

    Department of Redundancy Department
    Supreme Emperor of Hyperbole
    http://www.FullCircleInspect.com/

  4. #4
    Join Date
    Jul 2010
    Location
    Summerville, South Carolina
    Posts
    116

    Default Re: Goofy P-trap

    Quote Originally Posted by Gunnar Alquist View Post
    So, this looks goofy, but I can't tell if it's wrong. Can someone comment?
    Here is a link to my website which tell all about vents, traps and trap arms.... http://www.summerville-home-inspecto...arms-and-vents


  5. #5
    Join Date
    Dec 2007
    Location
    Holladay, UT
    Posts
    577

    Default Re: Goofy P-trap

    Great article Ray.

    Tom Rees / A Closer Look Home Inspection / Salt Lake City, Utah
    http://acloserlookslc.com/

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •