    Default Composition boot used for flashing

    I believe this one falls under the 1"(and common sense) to combustibles rule. I am posting it to be sure there is no rule that allows this. An ordinary composition boot is used for the flashing for the water heater flue. I also noted the missing cap. The furnace flue was a different issue.

    Thanks for input.

    Similar Threads:
    ***IMPORTANT*** You Need To Register To View Images ***IMPORTANT*** You Need To Register To View Images
    OREP Insurance

  2. #2
    Join Date
    Mar 2007
    Location
    Plano, Texas
    Posts
    4,245

    Default Re: Composition boot used for flashing

    No exception allowing this, 1" clearance to combustibles would specifically prohibit plus the need to use the listed flashing component with the b-vent.
    Don't forget the height of the flue above the roof.

    Jim Luttrall
    www.MrInspector.net
    Plano, Texas

  3. #3
    allen elliott's Avatar
    allen elliott Guest

    Default Re: Composition boot used for flashing

    Thanks Jim!