Registration is FREE!... and will get rid of this top message
Welcome to InspectionNews.net.
You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.
There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.
Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!
Registration is FREE, fast and easy so please, join InspectionNews today!
Why join InspectionNews? Read the Testimonials
Looking for Education? We recommend Casey, O'Malley and Associates

If you have any problems with the registration process or your account login, please contact us.
|
|

11-19-2008, 05:22 PM
|
 |
Member
|
|
Join Date: Mar 2008
Location: Charlotte NC
Posts: 613
|
|
|
Gas meter access.
Remodeled home today, rear porch was extended over the gas meter. The access panel opening is less than 22" by 24" (UPC 1209.5) probably not relavent but IRC has nothing I could find.
The 2006 N.C. Fuel Gas Code 401.9 states
"Accessible and Acceptable Location
A meter location, when required, shall be provided for the building or premises to be served. Gas metes shall be readily accessivle for inspection, reading, and replacement. Location, space requirements, dimensions, and type of installation shall be acceptable to the gas company."
(Code man speak with forked tongue)
What do I put in the report? "Recommend letter of acceptable installation be obtained from the gas co. prior to cllosing."?
Thoughts......anyone!
|
|

11-19-2008, 05:37 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,734
|
|
|
Re: Gas meter access.
Originally Posted by Vern Heiler
Remodeled home today, rear porch was extended over the gas meter. The access panel opening is less than 22" by 24" (UPC 1209.5) probably not relavent but IRC has nothing I could find.
The 2006 N.C. Fuel Gas Code 401.9 states
"Accessible and Acceptable Location
A meter location, when required, shall be provided for the building or premises to be served. Gas metes shall be readily accessivle for inspection, reading, and replacement. Location, space requirements, dimensions, and type of installation shall be acceptable to the gas company."
(Code man speak with forked tongue)
What do I put in the report? "Recommend letter of acceptable installation be obtained from the gas co. prior to closing."?
Thoughts......anyone!
The utility company has the final say in the matter.
You could report it just like you wrote. One thing however, I doubt they will get a letter from anyone saying it is OK. Might be best to simply tell them it is under the deck and that they should check with the gas company to see if that location is OK.
|
|

11-19-2008, 05:44 PM
|
|
Member
|
|
Join Date: Aug 2008
Location: Frankfort, Kentucky
Posts: 10
|
|
|
Re: Gas meter access.
Vern,
Your verbige sounds good to me to protect your buyer and you. Here in KY, the gas company is king - they can come into an existing home that met all gas, etc. codes when built (even fairly new ones -less than 10 years old) and after a meter upgrade, demand venting changes or they red tag/turn off gas! That happened to a client of mine, and I had to explain how the gas appliance was code approved in the past (inspection tag on water heater), codes changed later and she had to do what they said. Needless to say, she wasn't happy and somehow it was my fault! Oh well...
|
|

11-19-2008, 05:57 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 3,632
|
|
|
Re: Gas meter access.
That meter location would not be acceptable in our area. The meter has to be accessible to the service person. They would not be lifting any decking material to be able to read the meter or to turn off / on the service.
I'd probably say that seller built that deck right over the meter without making a single call to the gas provider.
rick
|
|

11-19-2008, 06:13 PM
|
 |
Member
|
|
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,233
|
|
|
Re: Gas meter access.
Originally Posted by Vern Heiler
Remodeled home today, rear porch was extended over the gas meter.
The 2006 N.C. Fuel Gas Code 401.9 states
"Accessible and Acceptable Location
Location, space requirements,
Thoughts......anyone!
.
Utility Company may be King ( But I find it hard to believe they were Consulted Before this Porch was Erected Over The Gas Meter.) 
.
see page 3 of attachment for 6 feet requirement for overhang ( does not even meet 3 feet to electrical outlet.)
.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Last edited by Billy Stephens : 11-19-2008 at 06:16 PM.
Reason: 3 feet added
|
|

11-19-2008, 06:33 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,734
|
|
|
Re: Gas meter access.
How and who is reading the meter?
|
|

11-19-2008, 06:34 PM
|
 |
Member
|
|
Join Date: Mar 2008
Location: Charlotte NC
Posts: 613
|
|
|
Re: Gas meter access.
Thanks for the input.
|
|

11-19-2008, 06:37 PM
|
 |
Member
|
|
Join Date: Mar 2008
Location: Charlotte NC
Posts: 613
|
|
|
Re: Gas meter access.
Originally Posted by Scott Patterson
How and who is reading the meter?
Most all of the water, gas & electric is read by radio signal from the meter to a meter reader driving down the street. They seldom go to the meter anymore.
|
|

11-19-2008, 06:58 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,178
|
|
|
Re: Gas meter access.
Originally Posted by Vern Heiler
What do I put in the report? "Recommend letter of acceptable installation be obtained from the gas co. prior to cllosing."?
Originally Posted by Scott Patterson
One thing however, I doubt they will get a letter from anyone saying it is OK. Might be best to simply tell them it is under the deck and that they should check with the gas company to see if that location is OK.
You should not care how hard it is to get that letter, and if the gas company is not willing to provide that letter, then their verbal okay is not going to hold any weight should anything happen.
Recommend they get the letter. It will protect your client and you.
The gas company will not be able to say 'We did not know it was THERE.'
|
|

11-19-2008, 07:36 PM
|
 |
Member
|
|
Join Date: Mar 2008
Location: Charlotte NC
Posts: 613
|
|
|
Re: Gas meter access.
The gas company will not be able to say 'We did not know it was THERE.'
That was my thought as well. I really don't think they know about it!
Thanks Jerry.
|
|

11-19-2008, 08:33 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Highland, IN
Posts: 574
|
|
|
Re: Gas meter access.
Originally Posted by Jerry Peck
Recommend they get the letter. It will protect your client and you.
'
Ya right! If his gas company is as bad as ours (NIPSCO), they tell the client what is wrong but wont put anything in writing. Then the new homeowner is upset because he doesn't understand everything the gas guy told him. Nice customer service. 
|
|

11-19-2008, 08:40 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Highland, IN
Posts: 574
|
|
|
Re: Gas meter access.
Originally Posted by Billy Stephens
.
Utility Company may be King ( But I find it hard to believe they were Consulted Before this Porch was Erected Over The Gas Meter.) 
.
see page 3 of attachment for 6 feet requirement for overhang ( does not even meet 3 feet to electrical outlet.)
.
Where else can that information be found? I looked in the International Gas Fuel Code book and I can't find anything that talks about the 3 foot clearance requirement. The local gas company enforces it but I cannot find where they get this information. It has to be available to the contractors or how else are they suppose to understand what is and is not allowed. Note: Most heating companies don't know about any clearance requirement.
|
|

11-19-2008, 09:09 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,178
|
|
|
Re: Gas meter access.
Originally Posted by Kevin Luce
Ya right! If his gas company is as bad as ours (NIPSCO), they tell the client what is wrong but wont put anything in writing.
Precisely.
And, by NOT issuing a letter stating that is it okay, that means IT IS *NOT* okay.
Which means: Correct it.
This is not rocket science stuff, guys.
If the utility company DOES NOT issue the letter stating it is correct, then it is NOT correct. As simple as that. When an agent, seller, whomever tries to disagree and say it is correct, all that needs to be said is: "The utility company REFUSED to say it was correct. If it is NOT CORRECT, then it is INCORRECT. FIX IT.
|
|

11-19-2008, 09:13 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,178
|
|
|
Re: Gas meter access.
Originally Posted by Kevin Luce
Where else can that information be found?
Here is one from Puget Sound Energy.
I believe those clearances are in NFPA 58.
|
|

11-20-2008, 06:37 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Peru,Illinois
Posts: 264
|
|
|
Re: Gas meter access.
One other consideration is that in case of emergency ( fire ) the fire dept. would have to search for the meter to turn it off, thereby wasting valuable time.
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Attic Access |
Jim Robinson |
General Chit Chat: Home Inspectors & Commercial Inspectors |
6 |
03-08-2008 04:26 PM |
| Attic access problems |
Brian E Kelly |
Attic Areas: Home Inspection and Commercial Inspection |
30 |
12-22-2007 06:28 AM |
| Attic Access Hatches |
Erol Kartal |
Attic Areas: Home Inspection and Commercial Inspection |
13 |
08-15-2007 08:46 AM |
| Attic Access Requirements |
dan orourke |
Attic Areas: Home Inspection and Commercial Inspection |
2 |
07-14-2007 08:18 PM |
| Furance Access. |
Jeff Eastman |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
1 |
05-02-2007 03:57 PM |
All times are GMT -7. The time now is 09:55 PM.
| | |
|