InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 04-02-2007, 04:50 PM
Trey Humphreys Trey Humphreys is offline
Member
 
Join Date: Mar 2007
Posts: 6
ABS Flue Pipe on LP Water Heater
Never seen this. Granted, I have only performed about 150 inspections but...
I have seen high efficiency furnaces / boilers with PVC exhaust but never a water heater with ABS... See photo. Any reason this is not acceptable? Also the entire set up is in a basement and the abs has about a 15' horizontal run before it daylights. It is fan assist exhaust but ABS?
(Please ignore extension chord...entirely different issue.)
Attached Images
File Type: jpg 100_3660.jpg (41.9 KB, 82 views)
File Type: jpg 100_3659.jpg (44.0 KB, 58 views)
Reply With Quote
IC Home Inspection Report Writing
  #2 (permalink)  
Old 04-02-2007, 04:54 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,796
Re: ABS Flue Pipe on LP Water Heater
Quote:
Originally Posted by Trey Humphreys View Post
Never seen this. Granted, I have only performed about 150 inspections but...
I have seen high efficiency furnaces / boilers with PVC exhaust but never a water heater with ABS... See photo. Any reason this is not acceptable? Also the entire set up is in a basement and the abs has about a 15' horizontal run before it daylights. It is fan assist exhaust but ABS?
(Please ignore extension chord...entirely different issue.)
Can't say I have ever seen it either. ABS is not approved for any type of gas appliance that I'm aware of.
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #3 (permalink)  
Old 04-02-2007, 05:01 PM
Richard Moore's Avatar
Richard Moore Richard Moore is offline
Member
 
Join Date: Mar 2007
Location: Seattle, WA
Posts: 349
Re: ABS Flue Pipe on LP Water Heater
This from a Rheem page at http://waterheating.rheem.com/Docume...PVGuardian.pdf

Flexible Venting
Options
Long venting lengths up to 100 feet

PVC, ABS, or CPVC vent pipe options

Vertical or horizontal termination

(my red)

Gotta say I would be doing a double-take too, but it seems it is OK.
__________________
Richard Moore
Rest Assured Inspection Services - www.rainspect.com
Seattle, Washington
Reply With Quote
  #4 (permalink)  
Old 04-02-2007, 05:05 PM
Scott Patterson's Avatar
Scott Patterson Scott Patterson is offline
Member
 
Join Date: Mar 2007
Location: Spring Hill (Nashville), TN
Posts: 2,796
Re: ABS Flue Pipe on LP Water Heater
I just looked up that same link. Surprise of the day!
__________________
Scott Patterson
Spring Hill, TN
http://www.traceinspections.com
Reply With Quote
  #5 (permalink)  
Old 04-02-2007, 05:20 PM
Trey Humphreys Trey Humphreys is offline
Member
 
Join Date: Mar 2007
Posts: 6
Re: ABS Flue Pipe on LP Water Heater
WOW! I agree... Surprise of the day!
Thanks!
Reply With Quote
  #6 (permalink)  
Old 04-03-2007, 01:18 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 811
Re: ABS Flue Pipe on LP Water Heater
I learn something every day.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #7 (permalink)  
Old 04-03-2007, 02:11 PM
Martin lehman's Avatar
Martin lehman Martin lehman is offline
Member
 
Join Date: Mar 2007
Location: San Diego, CA
Posts: 79
Re: ABS Flue Pipe on LP Water Heater
I see them all the time out here on new construction.
Reply With Quote
HomeGauge Reports
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 07:06 AM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger