You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 08-15-2007, 07:49 PM
Joshua Hardesty Joshua Hardesty is offline
Member
 
Join Date: Mar 2007
Posts: 117
Vents and detached structures
Can anybody explain to me why a detached structure needs a 2" vent through the roof?

Said system ties onto the main house, it does not have its own sewer system.
Reply With Quote
  #2 (permalink)  
Old 08-15-2007, 08:10 PM
Rick Cantrell Rick Cantrell is online now
Member
 
Join Date: Mar 2007
Location: Columbus GA
Posts: 387
Re: Vents and detached structures
You are not giving us much information to go on.
If there are any drains in the detached building the drain must also have a vent within 5' (? on 5').
__________________
Rick Cantrell
Columbus GA
Reply With Quote
  #3 (permalink)  
Old 08-15-2007, 08:30 PM
Joshua Hardesty Joshua Hardesty is offline
Member
 
Join Date: Mar 2007
Posts: 117
Re: Vents and detached structures
Sorry, it was just meant as an abstract question. The structure has a full bathroom and a kitchen sink. The bathroom is vented, properly, through the sink. It's on a 2x1.5"x1.5" tee that then goes out through the roof on the 1.5" pipe. The toilet is on a 3" pipe (and so is the structure) so there's no issue with the vent being less than half the size of the pipe it's venting. Further downstream is the kitchen sink, which is stubbed up through the floor and will have an AAV installed at trim-out.
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Garage Vents Charles Smith Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 8 07-11-2007 10:45 AM
Soffit Vents Jim Luttrall Attic Areas: Home Inspection and Commercial Inspection 22 06-28-2007 04:04 PM
Combustion air vents John Stephenson Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 2 06-01-2007 08:30 PM
What are these vents for? Terry Beck Sub-Structure: Home Inspection and Commercial Inspection 14 05-21-2007 05:09 AM
Vents Warren Alderman Attic Areas: Home Inspection and Commercial Inspection 26 04-14-2007 12:35 PM


All times are GMT -7. The time now is 12:04 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger