You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

08-22-2007, 11:23 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
|
|
|
Water Heater Vent Connection
What say ye regarding this water heater vent connection?
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

08-23-2007, 01:59 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Oregon
Posts: 661
|
|
|
Re: Water Heater Vent Connection
It's ugly... the single wall part looks like it's too close to the wall and the transition before the ceiling almost looks homemade. I'd be curious to see what it does above the the ceiling.
|
|

08-23-2007, 10:42 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
|
|
|
Re: Water Heater Vent Connection
It's no prettier there, Matt. It has no clearance at all where it penetrates a wall and ceiling of the bathroom. (The waterstains around the waste pipe at the ceiling are another issue.)
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

08-23-2007, 12:07 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 337
|
|
|
Re: Water Heater Vent Connection
Any combustion air??
|
|

08-23-2007, 12:24 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
|
|
|
Re: Water Heater Vent Connection
The water heater sits in a large laundry room. Combustion air is not an issue.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

08-23-2007, 05:28 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
|
|
|
Re: Water Heater Vent Connection
Originally Posted by Bruce Breedlove
The water heater sits in a large laundry room. Combustion air is not an issue.
With a gas dryer?
*HOW* "large"?
|
|

08-23-2007, 08:04 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Barrington, IL
Posts: 396
|
|
|
Re: Water Heater Vent Connection
Gas or electric dryer, both will depressurize a room.
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
|
|

08-23-2007, 11:28 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
|
|
|
Re: Water Heater Vent Connection
Originally Posted by Jerry Peck
With a gas dryer?
*HOW* "large"?
Electric dryer. But point taken.
If room depressurization from a dryer is a concern at the loose vent connection would it not also be a concern at the hood?
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

08-24-2007, 08:21 PM
|
 |
Member
|
|
Join Date: May 2007
Location: Frankfort, KY
Posts: 179
|
|
|
Re: Water Heater Vent Connection
Originally Posted by Bruce Breedlove
Electric dryer. But point taken.
If room depressurization from a dryer is a concern at the loose vent connection would it not also be a concern at the hood?
The difference is the draft hood is a designed hole where the other is a unintentional hole.
There is a big difference.
I really hope you don't take that statement seriously but I have been told that exact statement before.
Yes it should be a concern Bruce as it can impact the appliances ability to vent.
Open draft hoods make for nice make up air inlets using the vent pipe as the duct if the room is in a negative pressure scenario.
__________________
Measured Performance more than just a buzzword
|
|

08-24-2007, 09:21 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
|
|
|
Re: Water Heater Vent Connection
Originally Posted by Eric Barker
Gas or electric dryer, both will depressurize a room.
Correct, however, gas adds in the additional combustion air needed to sustain combustion, and all that combustion air, in addition to the exhaust air, needs to be made up with make up air.
Thus, gas is worse than electric.
|
|

08-25-2007, 10:06 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Pa.
Posts: 577
|
|
|
simple arithmetic
for every cubic foot of air leaving the room, an equal measure must replace it-period! Nature abhors imbalances. That's where we get this "path of least resistance" stuff. It will find a way. Now, we can control where or we can leave it to nature where we may not like her choice (backdraft) but it will happen one way or another.
__________________
disgusted with some people on this forum. Out of here!
|
|

08-30-2007, 01:51 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Michigan
Posts: 157
|
|
|
Re: Water Heater Vent Connection
The water heater venting is improper and unsafe. Repair or replace. Combustibles too close.
|
|

08-30-2007, 02:57 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
|
|
|
Re: Water Heater Vent Connection
That's pretty much what I reported. If the new water heater had been permitted the improper vent might have been avoided.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
|
|

08-30-2007, 03:42 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
|
|
|
Re: Water Heater Vent Connection
Originally Posted by Bruce Breedlove
If the new water heater had been permitted the improper vent might have been avoided.
Huh?
What world do you live in?
The inspector would have probably just signed it off. 
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Water HEater Vent |
Clay E White |
Plumbing System: Home Inspection and Commercial Inspection |
3 |
08-21-2007 01:29 PM |
| Water heater vent pipe |
wayne soper |
Plumbing System: Home Inspection and Commercial Inspection |
3 |
07-25-2007 06:46 PM |
| Water Heater |
Jeff Eastman |
Plumbing System: Home Inspection and Commercial Inspection |
5 |
07-23-2007 06:31 PM |
| Armstrong Oil Fired Furnace / Vent Connection |
Joseph P. Hagarty |