InspectionNews - Home Inspection



Welcome to the InspectionNews - Home Inspection forums.

You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 08-22-2007, 11:23 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
Water Heater Vent Connection
What say ye regarding this water heater vent connection?
Attached Images
File Type: jpg WH02.JPG (46.8 KB, 118 views)
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #2 (permalink)  
Old 08-23-2007, 01:59 AM
Matt Fellman Matt Fellman is offline
Member
 
Join Date: Mar 2007
Location: Oregon
Posts: 661
Re: Water Heater Vent Connection
It's ugly... the single wall part looks like it's too close to the wall and the transition before the ceiling almost looks homemade. I'd be curious to see what it does above the the ceiling.
Reply With Quote
  #3 (permalink)  
Old 08-23-2007, 10:42 AM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
Re: Water Heater Vent Connection
It's no prettier there, Matt. It has no clearance at all where it penetrates a wall and ceiling of the bathroom. (The waterstains around the waste pipe at the ceiling are another issue.)
Attached Images
File Type: jpg I93.JPG (46.6 KB, 62 views)
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #4 (permalink)  
Old 08-23-2007, 12:07 PM
Richard Stanley Richard Stanley is offline
Member
 
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 337
Re: Water Heater Vent Connection
Any combustion air??
Reply With Quote
  #5 (permalink)  
Old 08-23-2007, 12:24 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
Re: Water Heater Vent Connection
The water heater sits in a large laundry room. Combustion air is not an issue.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #6 (permalink)  
Old 08-23-2007, 05:28 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Water Heater Vent Connection
Quote:
Originally Posted by Bruce Breedlove View Post
The water heater sits in a large laundry room. Combustion air is not an issue.
With a gas dryer?

*HOW* "large"?
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #7 (permalink)  
Old 08-23-2007, 08:04 PM
Eric Barker's Avatar
Eric Barker Eric Barker is offline
Member
 
Join Date: Mar 2007
Location: Barrington, IL
Posts: 396
Re: Water Heater Vent Connection
Gas or electric dryer, both will depressurize a room.
__________________
Eric Barker
Moraine Woods Consulting, Inc.
Barrington, IL
Reply With Quote
  #8 (permalink)  
Old 08-23-2007, 11:28 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
Re: Water Heater Vent Connection
Quote:
Originally Posted by Jerry Peck View Post
With a gas dryer?

*HOW* "large"?
Electric dryer. But point taken.

If room depressurization from a dryer is a concern at the loose vent connection would it not also be a concern at the hood?
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #9 (permalink)  
Old 08-24-2007, 08:21 PM
DavidR's Avatar
DavidR DavidR is offline
Member
 
Join Date: May 2007
Location: Frankfort, KY
Posts: 179
Re: Water Heater Vent Connection
Quote:
Originally Posted by Bruce Breedlove View Post
Electric dryer. But point taken.

If room depressurization from a dryer is a concern at the loose vent connection would it not also be a concern at the hood?

The difference is the draft hood is a designed hole where the other is a unintentional hole.
There is a big difference.

I really hope you don't take that statement seriously but I have been told that exact statement before.

Yes it should be a concern Bruce as it can impact the appliances ability to vent.
Open draft hoods make for nice make up air inlets using the vent pipe as the duct if the room is in a negative pressure scenario.
__________________
Measured Performance more than just a buzzword
Reply With Quote
  #10 (permalink)  
Old 08-24-2007, 09:21 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Water Heater Vent Connection
Quote:
Originally Posted by Eric Barker View Post
Gas or electric dryer, both will depressurize a room.
Correct, however, gas adds in the additional combustion air needed to sustain combustion, and all that combustion air, in addition to the exhaust air, needs to be made up with make up air.

Thus, gas is worse than electric.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #11 (permalink)  
Old 08-25-2007, 10:06 AM
Bob Harper's Avatar
Bob Harper Bob Harper is offline
Member
 
Join Date: Mar 2007
Location: Pa.
Posts: 577
simple arithmetic
for every cubic foot of air leaving the room, an equal measure must replace it-period! Nature abhors imbalances. That's where we get this "path of least resistance" stuff. It will find a way. Now, we can control where or we can leave it to nature where we may not like her choice (backdraft) but it will happen one way or another.
__________________
disgusted with some people on this forum. Out of here!
Reply With Quote
  #12 (permalink)  
Old 08-30-2007, 01:51 PM
Randy Aldering Randy Aldering is offline
Member
 
Join Date: Mar 2007
Location: Michigan
Posts: 157
Re: Water Heater Vent Connection
The water heater venting is improper and unsafe. Repair or replace. Combustibles too close.
__________________
Randy Aldering, RHI CHI
Housesmithe Home Inspection
www.housesmithe.com
Reply With Quote
  #13 (permalink)  
Old 08-30-2007, 02:57 PM
Bruce Breedlove's Avatar
Bruce Breedlove Bruce Breedlove is offline
Member
 
Join Date: Mar 2007
Location: Colorado Springs, CO
Posts: 677
Re: Water Heater Vent Connection
That's pretty much what I reported. If the new water heater had been permitted the improper vent might have been avoided.
__________________
"Baseball is like church. Many attend but few understand." Leo Durocher
Bruce Breedlove
www.avaloninspection.com
Reply With Quote
  #14 (permalink)  
Old 08-30-2007, 03:42 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Water Heater Vent Connection
Quote:
Originally Posted by Bruce Breedlove View Post
If the new water heater had been permitted the improper vent might have been avoided.
Huh?

What world do you live in?

The inspector would have probably just signed it off.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Water HEater Vent Clay E White Plumbing System: Home Inspection and Commercial Inspection 3 08-21-2007 01:29 PM
Water heater vent pipe wayne soper Plumbing System: Home Inspection and Commercial Inspection 3 07-25-2007 06:46 PM
Water Heater Jeff Eastman Plumbing System: Home Inspection and Commercial Inspection 5 07-23-2007 06:31 PM
Armstrong Oil Fired Furnace / Vent Connection Joseph P. Hagarty Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 6 06-27-2007 07:47 AM
Upsized water heater vent pipe Jeff Eastman Plumbing System: Home Inspection and Commercial Inspection 2 04-30-2007 11:32 AM


All times are GMT -7. The time now is 01:53 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger