You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

09-12-2007, 02:10 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: gone
Posts: 245
|
|
|
p-trap
.........
Last edited by Jeff Eastman : 11-27-2007 at 07:33 PM.
|
|

09-12-2007, 03:05 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Seattle, WA
Posts: 227
|
|
|
Re: p-trap
I'd say that if you can't see it with the naked eye...and I can't...then, yes, it's too damn small!
|
|

09-12-2007, 04:35 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,086
|
|
|
Re: p-trap
.....
__________________
"If con is the opposite of pro, is Congress the opposite of progress?"
Richard Rushing, HCRI
Duncanville, Tx.
|
|

09-12-2007, 05:27 PM
|
 |
Member
|
|
Join Date: Aug 2007
Location: Memphis TN.
Posts: 1,401
|
|
|
Re: p-trap
Jeff,
Thanks for the Laugh!
Stay Tuned for the come backs. Baby bumpers,Wife said too big, Larger size made him feel, ect. ect ect.
The way the mini - trap connects at the top looks like it's (should I say it) nope askew.
Looks like a leaker when system is at capacity.
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
|
|

09-12-2007, 05:35 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Dallas, Texas
Posts: 1,449
|
|
|
Re: p-trap
Did this have the ADA protectors on the drain as well as the supply lines?
Those can really disguise the dimensions.
__________________
Jim Luttrall
Mr. Inspector.net, Inc.
Allen, Texas 75002
|
|

09-12-2007, 05:49 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: gone
Posts: 245
|
|
|
Re: p-trap
No ADA anywhere I could visibly see.
Thanks, I 'll write it up as an improperly sized trap system.
|
|

09-12-2007, 06:34 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,641
|
|
|
Re: p-trap
Originally Posted by Jeff Eastman
No ADA anywhere I could visibly see.
Thanks, I 'll write it up as an improperly sized trap system.
I would not say "improperly sized trap" as that trap looks to be "properly sized".
I would simply state improperly trapped, which includes the tailpiece (lack thereof) and improper bends. Unless that is an actual approved trap system, those 90 degree bends should have a larger radius to them - those look like pressure fittings, not DWV fittings - not the trap is glued up into the 90 degree elbow above, creating a lip to catch debris on and clog the trap (unless this is actually an approved trap system, in which case the inside of the 90 elbow above would be reduce to match up with the inside of the piece below.
|
|

09-13-2007, 06:34 AM
|
|
Member
|
|
Join Date: Mar 2007
Location: Longwood, FL
Posts: 288
|
|
|
Re: p-trap
I'm surprised you guys have never seen this before, it is a very common off-set tailpiece/trap assembly for wheelchair applications. Typically found in commercial buildings following ADA requirements for clear space below the sink.
Here is one version:
Click here for specs
Dom.
|
|

09-13-2007, 07:31 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 286
|
|
|
Re: p-trap
Ok.... look at the enclosed pic.
"s" trap
"p" trap
and..... once it goes through the wall......and does a 90*......??????
Or....Does the 7" horizontal arm make it a "P" trap?
|
|

09-13-2007, 09:02 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Land of Gar, TX
Posts: 391
|
|
|
Re: p-trap
I've inspected 3 homes that were ADA converted at all locations.
The potential purchasers at one were concerned about the conversions meeting current codes and wanted the city to disallow so the sellers would have to pay and make the perceived repairs or adjust the sales price.
City told 'em to p up a rope.
I just scratched my head and thought to myself look for another house if these modifications bother you.
Why bother entering into a contract if you don't like the house in it's current condition? I'm never surprised as to what or how people think anymore.
__________________
badair http://www.adairinspection.com Garland, TX 75042
Residential-Commercial-Construction-EIFS-Infrared Thermography
life is the random lottery of events followed by numerous narrow escapes
|
|

09-17-2007, 08:08 PM
|
|
Member
|
|
Join Date: Mar 2007
Posts: 112
|
|
|
Re: p-trap
Originally Posted by Victor DaGraca
Ok.... look at the enclosed pic.
"s" trap
"p" trap
and..... once it goes through the wall......and does a 90*......??????
Or....Does the 7" horizontal arm make it a "P" trap?
An "S" trap goes down, then goes up, then goes down again before reaching a vent within the required distances. (i.e., a 1.5" "P" trap with an 8 foot horizontal span is still an "S" trap, just not as obvious as the "S" traps you can buy at Lowes.)
Nuffin' wrong with the P-trap, except...
It could possibly be a crown vent, if the distance from the trap to the vent is less than twice the pipe diameter. But that's hard to tell from the photo.
So, if there's a vent in the wall not too far away, but at least 2.5" away for a 1.25" trap, or 3" away for a 1.5" trap, that configuration is fine.
|
|

09-17-2007, 08:15 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 6,641
|
|
|
Re: p-trap
I've been keeping my eye out and looking at the traps at sinks in toilet stalls at various places and, yep, I guess I just never paid much attention to them, but those are the types used for accessible toilet stalls and the like.
Just saw another one today and thought 'how could I have not noticed them before?' Oh well, I didn't. 
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Is This An 'S' Trap? |
Bruce Breedlove |
Plumbing System: Home Inspection and Commercial Inspection |
6 |
08-03-2007 07:13 PM |
| Definition of a trap arm. |
Bob Mayer |
Plumbing System: Home Inspection and Commercial Inspection |
1 |
07-15-2007 05:25 PM |
| Double p-trap? |
John Stephenson |
Plumbing System: Home Inspection and Commercial Inspection |
8 |
06-11-2007 08:39 PM |
| p-trap |
John Stephenson |
Plumbing System: Home Inspection and Commercial Inspection |
7 |
05-16-2007 04:28 PM |
| trap |
wayne soper |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
4 |
05-06-2007 12:11 PM |
All times are GMT -7. The time now is 10:35 PM.
| | |
|