InspectionNews - Home Inspection



Welcome to the InspectionNews - Home Inspection forums.

You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 12-12-2007, 04:40 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 146
Circulator Attached to Direct Vent Wtr Htr
50 gallon, direct vent, natural gas water heater in garage on 18 inch stand. There is a pipe connected to the water heater about a foot above the burner into the side of the water heater. Installed in the pipe is a Circulator Taco Cartridge that has a power cord. Power cord is not plugged in. No solar water heater panels were observed.

Not sure what a Circulator Taco Cartridge is. Any guesses?

Someone was talking to me on the phone while I was taking the pictures distracting me and I thought I got enough. Now I am not sure.
Attached Images
File Type: jpg DSCN1810.JPG (74.9 KB, 24 views)
File Type: jpg DSCN1811.JPG (69.5 KB, 18 views)
File Type: jpg DSCN1814.JPG (81.3 KB, 17 views)
File Type: jpg DSCN1813.JPG (76.8 KB, 23 views)
File Type: jpg DSCN1812.JPG (82.8 KB, 12 views)
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
  #2 (permalink)  
Old 12-12-2007, 04:44 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,398
Re: Circulator Attached to Direct Vent Wtr Htr
Bruce,

It looks like it is a re-circulatory pump. Most I see are unplugged also.

rick
Reply With Quote
  #3 (permalink)  
Old 12-12-2007, 05:11 PM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 1,606
Re: Circulator Attached to Direct Vent Wtr Htr
Bruce,

I'm not sure about the Taco.

But as you have posted the pictures,

The flue looks to Flat needs (1/4 " per foot up slope.)

The pipe insulation can not be in contact with the flue as it is combustible.


Here you Go!

www.nextag.com/taco-cartridge-circulator/search-html
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.

Last edited by Billy Stephens : 12-12-2007 at 05:24 PM. Reason: link added
Reply With Quote
  #4 (permalink)  
Old 12-12-2007, 05:15 PM
Victor DaGraca's Avatar
Victor DaGraca Victor DaGraca is offline
Member
 
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 325
Re: Circulator Attached to Direct Vent Wtr Htr
I love google.....

Taco 006 Pump, Taco 007 Pump, Taco Pumps 008, Taco Pumps 009, Taco Pump 0010, Taco Pumps 0011
__________________
Critical Home Inspection Services
www.Home2Spec.com
Reply With Quote
  #5 (permalink)  
Old 12-12-2007, 05:49 PM
Bruce Ramsey's Avatar
Bruce Ramsey Bruce Ramsey is offline
Member
 
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 146
Re: Circulator Attached to Direct Vent Wtr Htr
Thanks to one and all. I forgot to check google myself. Silly me.

I just assumed it to be some home inspector thing I didn't know about.

This house had a number of "upgrades". Whoever lived there was a very busy person. They had a cat door through the kitchen wall that lead into a bench seat on the deck. The bench seat was enclosed on all sides. Inside the bench seat was a ramp down to grade. Under the deck was enclosed in wire mesh. Kitty could go outside but be still be contained at the same time. There was an opening in the mesh that led to another mesh box. It was the litter box. Under the deck was covered with gravel.
Attached Images
File Type: jpg DSCN1788.JPG (94.2 KB, 13 views)
File Type: jpg DSCN1789.JPG (90.1 KB, 13 views)
File Type: jpg DSCN1792.JPG (104.7 KB, 11 views)
File Type: jpg DSCN1793.JPG (108.6 KB, 10 views)
File Type: jpg DSCN1794.JPG (96.9 KB, 10 views)
File Type: jpg DSCN1795.JPG (95.5 KB, 8 views)
File Type: jpg DSCN1797.JPG (88.4 KB, 8 views)
File Type: jpg DSCN1837.JPG (77.9 KB, 6 views)
File Type: jpg DSCN1784.JPG (104.3 KB, 8 views)
__________________
Bruce Ramsey
Advocate Inspections
www.NCAdvocate.com
Reply With Quote
  #6 (permalink)  
Old 12-12-2007, 06:19 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
Re: Circulator Attached to Direct Vent Wtr Htr
Recirculating pump, does not do any good if not plugged in.

Recirculating pump wired with extension cord with end cut off - NOT GOOD. Needs to have a receptacle outlet down within reach of a standard appliance cord, of the cord and plug which came with that if it came with a cord and plug. Also, a proper (and properly installed) cord strain relief clamp is needed at the pump.

Nothing is holding that T&P CPVC (looks like CPVC) discharge line in place, that thing could move around under emergency discharge conditions.

Are you sure that is direct vent? You mean fan assisted? Looks like a blower fan on top.
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #7 (permalink)  
Old 12-12-2007, 06:55 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,398
Re: Circulator Attached to Direct Vent Wtr Htr
Bruce,

That is one pampered cat.

Reminds me though of a T-shirt I saw this guy wearing the other day.

It said, "I Love Cats.. I just can't eat a whole one by myself"

The ones I like is the people who have a complete homemade HVAC system set up for the exterior dog house.
__________________
Rick Hurst_Home Works Inspection Co_Rockwall TX
In the words of Mike Tyson.... "Everyone has a plan until they get hit inda mouf"
Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Combustion Air venting for Direct Vent FPs Clay White Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 4 10-17-2007 04:23 PM
Direct vent location Clay E White Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 4 09-24-2007 07:01 AM
Gas fireplace direct vent location Jon mackay Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 14 07-11-2007 07:16 PM
Gray PVC for direct vent furnace Jon mackay Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection 0 06-08-2007 05:52 AM
LP tank near direct vent Frank Bombardiere Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 1 05-22-2007 07:11 PM


All times are GMT -7. The time now is 01:40 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger