Welcome to the InspectionNews - Home Inspection forums.
You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

12-12-2007, 04:40 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 146
|
|
|
Circulator Attached to Direct Vent Wtr Htr
50 gallon, direct vent, natural gas water heater in garage on 18 inch stand. There is a pipe connected to the water heater about a foot above the burner into the side of the water heater. Installed in the pipe is a Circulator Taco Cartridge that has a power cord. Power cord is not plugged in. No solar water heater panels were observed.
Not sure what a Circulator Taco Cartridge is. Any guesses?
Someone was talking to me on the phone while I was taking the pictures distracting me and I thought I got enough. Now I am not sure.
|
|

12-12-2007, 04:44 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,398
|
|
|
Re: Circulator Attached to Direct Vent Wtr Htr
Bruce,
It looks like it is a re-circulatory pump. Most I see are unplugged also.
rick
|
|

12-12-2007, 05:11 PM
|
 |
Member
|
|
Join Date: Aug 2007
Location: Memphis TN.
Posts: 1,606
|
|
|
Re: Circulator Attached to Direct Vent Wtr Htr
Bruce,
I'm not sure about the Taco.
But as you have posted the pictures,
The flue looks to Flat needs (1/4 " per foot up slope.)
The pipe insulation can not be in contact with the flue as it is combustible.
Here you Go!
www.nextag.com/taco-cartridge-circulator/search-html
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Last edited by Billy Stephens : 12-12-2007 at 05:24 PM.
Reason: link added
|
|

12-12-2007, 05:15 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 325
|
|
|
Re: Circulator Attached to Direct Vent Wtr Htr
|
|

12-12-2007, 05:49 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Raleigh, North Carolina
Posts: 146
|
|
|
Re: Circulator Attached to Direct Vent Wtr Htr
Thanks to one and all. I forgot to check google myself. Silly me.
I just assumed it to be some home inspector thing I didn't know about.
This house had a number of "upgrades". Whoever lived there was a very busy person. They had a cat door through the kitchen wall that lead into a bench seat on the deck. The bench seat was enclosed on all sides. Inside the bench seat was a ramp down to grade. Under the deck was enclosed in wire mesh. Kitty could go outside but be still be contained at the same time. There was an opening in the mesh that led to another mesh box. It was the litter box. Under the deck was covered with gravel.
|
|

12-12-2007, 06:19 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,648
|
|
|
Re: Circulator Attached to Direct Vent Wtr Htr
Recirculating pump, does not do any good if not plugged in.
Recirculating pump wired with extension cord with end cut off - NOT GOOD. Needs to have a receptacle outlet down within reach of a standard appliance cord, of the cord and plug which came with that if it came with a cord and plug. Also, a proper (and properly installed) cord strain relief clamp is needed at the pump.
Nothing is holding that T&P CPVC (looks like CPVC) discharge line in place, that thing could move around under emergency discharge conditions.
Are you sure that is direct vent? You mean fan assisted? Looks like a blower fan on top.
|
|

12-12-2007, 06:55 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,398
|
|
|
Re: Circulator Attached to Direct Vent Wtr Htr
Bruce,
That is one pampered cat.
Reminds me though of a T-shirt I saw this guy wearing the other day.
It said, "I Love Cats.. I just can't eat a whole one by myself"
The ones I like is the people who have a complete homemade HVAC system set up for the exterior dog house.
__________________
Rick Hurst_Home Works Inspection Co_Rockwall TX
In the words of Mike Tyson.... "Everyone has a plan until they get hit inda mouf"
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Combustion Air venting for Direct Vent FPs |
Clay White |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
4 |
10-17-2007 04:23 PM |
| Direct vent location |
Clay E White |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
4 |
09-24-2007 07:01 AM |
| Gas fireplace direct vent location |
Jon mackay |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
14 |
07-11-2007 07:16 PM |
| Gray PVC for direct vent furnace |
Jon mackay |
Heating, Ventilation, Air Conditioning (HVAC): Home Inspection and Commercial Inspection |
0 |
06-08-2007 05:52 AM |
| LP tank near direct vent |
Frank Bombardiere |
Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection |
1 |
05-22-2007 07:11 PM |
All times are GMT -7. The time now is 01:40 PM.
| | |
|