InspectionNews - Home Inspection



Registration is FREE!... and will get rid of this top message

Welcome to InspectionNews.net.

You are currently viewing InspectionNews as a guest which gives you limited access to view some discussions but none of the pictures.

There are over 9,970 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, post new topics or reply to others, communicate privately with other members, respond to polls, upload content and access many other special features.

Registration is FREE for you because the sponsors pay your way. Please visit the sponsors often and let them know that you found them on InspectionNews!

Registration is FREE, fast and easy so please, join InspectionNews today!

Why join InspectionNews? Read the Testimonials

Looking for Education? We recommend Casey, O'Malley and Associates
Home and Commercial Inspection Education

If you have any problems with the registration process or your account login, please contact us.

Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 01-30-2008, 06:22 AM
Jerome W. Young Jerome W. Young is offline
Member
 
Join Date: Dec 2007
Location: Vero Beach Florida
Posts: 264
proper supply piping/ air gap at dishwasher
is this burst resistant hose ok to use in this application? this heater is under a kitchen counter.

yes it needs a tpr pipe

Anyone know any reason why this should not have an sir gap or high loop? the drain line comes from the bottom of the dishwasher and directly to the disposal
Attached Images
File Type: jpg DSC08069.jpg (40.5 KB, 45 views)
File Type: jpg DSC08070.jpg (33.0 KB, 40 views)
Reply With Quote
  #2 (permalink)  
Old 01-30-2008, 07:05 AM
Billy Stephens's Avatar
Billy Stephens Billy Stephens is online now
Member
 
Join Date: Aug 2007
Location: Memphis TN.
Posts: 2,278
Re: proper supply piping/ air gap at dishwasher
Quote:
Originally Posted by Jerome W. Young View Post
is this burst resistant hose ok to use in this application? this heater is under a kitchen counter.

yes it needs a tpr pipe

Anyone know any reason why this should not have an sir gap or high loop? the drain line comes from the bottom of the dishwasher and directly to the disposal
Jerome,

1. I'd say no on the flex line.(See AO Smith attachment)

2.NO! on the dishwasher unless you like disposal water circulating in your dishwasher.
Attached Images
File Type: pdf AO Smith Electric.pdf (48.2 KB, 16 views)
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
Reply With Quote
  #3 (permalink)  
Old 01-30-2008, 07:59 AM
Jerry Peck's Avatar
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 14,297
Re: proper supply piping/ air gap at dishwasher
I agree with Billy ... with some hesitation on the dishwasher high loop - because the dishwasher could - COULD - *COULD* - but might not , have a built in high loop.

I always wrote them up and let a plumber verify that it either had one or they install one.

Also, no clamp at the disposer connection and that dishwasher drain hose could come off, making a real mess real fast.

Also sure that you caught the missing plate at the receptacle back there.

I know you said the T&P needs a relief line, but consider 'how' it is going to be added ...
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
www.AskCodeMan.com
Reply With Quote
  #4 (permalink)  
Old 01-30-2008, 09:23 AM
Jerome W. Young Jerome W. Young is offline
Member
 
Join Date: Dec 2007
Location: Vero Beach Florida
Posts: 264
Re: proper supply piping/ air gap at dishwasher
i dont know on the pipe may cpvc will make it possible. either way I made a note of it and they canfigure it out
Reply With Quote
  #5 (permalink)  
Old 01-30-2008, 10:20 AM
Richard Rushing's Avatar
Richard Rushing Richard Rushing is offline
Member
 
Join Date: Mar 2007
Location: Duncanville, Tx
Posts: 1,097
Re: proper supply piping/ air gap at dishwasher
Also, at a minimum, the hot water side supply line of the water heater should be insulated.

It can't be visually identified by the photo, but since that sucker is inside the home, it needs a drain pan-- was one present?

RR
__________________
"If con is the opposite of pro, is Congress the opposite of progress?"
Richard Rushing, HCRI
Duncanville, Tx.
Reply With Quote
  #6 (permalink)  
Old 01-30-2008, 11:33 AM
Jerome W. Young Jerome W. Young is offline
Member
 
Join Date: Dec 2007
Location: Vero Beach Florida
Posts: 264
Re: proper supply piping/ air gap at dishwasher
yes a pan was present believe it or not.

Thanks All
Reply With Quote
Home inspection - The Cost Of Business.
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
CTSX Piping Jerome W. Young Plumbing System: Home Inspection and Commercial Inspection 9 12-28-2007 11:32 AM
galvanized piping Scott Lynch Plumbing System: Home Inspection and Commercial Inspection 5 07-22-2007 07:36 PM
Dishwasher Inspection Rick Hurst Built-In Appliances and Systems: Home Inspection and Commercial Inspection 22 06-29-2007 04:14 AM
Dishwasher David Banks Plumbing System: Home Inspection and Commercial Inspection 3 05-21-2007 07:51 PM
GE dishwasher recall John Arnold Built-In Appliances and Systems: Home Inspection and Commercial Inspection 2 05-16-2007 04:55 PM

Alabama | Alaska | Arizona | Atlanta | Aurora | Austin | Baltimore | Boston | California | Cambridge | Cape Coral | Chandler | Charlotte | Chicago | Cincinnati | Clarksville | Cleveland | Colorado | Columbus | Connecticut | Dallas | Delaware | Denver | Detroit | Durham | El Paso | Eugene | Florida | Fort Worth | Fresno | Georgia | Gilbert | Hawaii | Henderson | Houston | Huntsville | Idaho | Illinois | Indiana | Indianapolis | Irvine | Jacksonville | Joliet | Kansas City | Knoxville | Lancaster | Las Vegas | Los Angeles | Louisiana | Louisville | Maine | Maryland | Massachusetts | Memphis | Mesa | Miami | Michigan | Milwaukee | Minneapolis | Minnesota | Miramar | Mississippi | Missouri | Montana | Nashville | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Oakland | Ohio | Oklahoma | Omaha | Ontario | Orange | Oregon | Orlando | Pennsylvania | Philadelphia | Phoenix | Pittsburgh | Plano | Portland | Port StLucie | Raleigh | Rhode Island | Roseville | Sacramento | Salem | San Antonio | San Diego | San Francisco | San Jose | Scottsdale | Seattle | Sioux falls | South Carolina | South Dakota | St Louis | Tampa | Tennessee | Texas | Thornton | Toledo | Tucson | Tulsa | Utah | Vancouver | Vermont | Virginia | West Virginia | Wichita | Wisconsin | Wyoming | Cost To Repair

All times are GMT -7. The time now is 01:33 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger