You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 02-26-2008, 07:15 PM
Gunnar Alquist's Avatar
Gunnar Alquist Gunnar Alquist is offline
Member
 
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 764
Landscape Sprinkler
Just had a question from a client regarding the necessity of anti-siphon valves on landscape sprinklers. Are they required when the house is supplied by a private well? I would think so, and reported as such, but since the query, I have been unable to find any specific code.
__________________
The apostrophe troll.
Reply With Quote
  #2 (permalink)  
Old 02-26-2008, 08:13 PM
Rick Hurst's Avatar
Rick Hurst Rick Hurst is offline
Member
 
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,417
Re: Landscape Sprinkler
Gunnar,

Here's a interesting read on the subject.

Irrigation Backflow Preventers
Reply With Quote
  #3 (permalink)  
Old 02-26-2008, 08:21 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,732
Re: Landscape Sprinkler
Quote:
Originally Posted by Gunnar Alquist View Post
Are they required when the house is supplied by a private well? I would think so, and reported as such, but since the query, I have been unable to find any specific code.

Gunnar,


P2902.1 General.
A potable water supply system shall be designed and installed as to prevent contamination from nonpotable liquids, solids or gases being introduced into the potable water supply. Connections shall not be made to a potable water supply in a manner that could contaminate the water supply or provide a cross-connection between the supply and a source of contamination unless an approved backflow-prevention device is provided. Cross-connections between an individual water supply and a potable public water supply shall be prohibited.

P2902.3 Backflow protection.


A means of protection against backflow shall be provided in accordance with Sections P2902.3.1 through P2902.3.6. Backflow prevention applications shall conform to Table P2902.3, except as specifically stated in Sections P2902.4 through P2902.5.5.
(followed by a listing of 6 types of backflow devices)

P2902.4 Protection of potable water outlets.


Potable water openings and outlets shall be protected by an air gap, reduced pressure principle backflow preventer with atmospheric vent, atmospheric-type vacuum breaker, pressure-type vacuum breaker or hose connection backflow preventer.
(followed by a listing of 3 examples)

I should add: I am presuming by your question that both the house and the landscape sprinkler system are provided by the same well.

__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
  #4 (permalink)  
Old 02-26-2008, 09:49 PM
Gunnar Alquist's Avatar
Gunnar Alquist Gunnar Alquist is offline
Member
 
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 764
Re: Landscape Sprinkler
Rick,

Thanks. Interesting read and good information. I particularly liked the reference to dihydrogen monoxide (H20). There is a really good website on that.

Jerry,

I don't inspect wells, just note them. However, I only recall one well. Interesting thought, though. If there were separate pressure tanks, each with its own check valve, this might be acceptable. Had not thought of that.

Thanks for the replies. The only obvious problem is that CA still does not use the IRC. It is reliable as a reference and no doubt has a UPC corollary.
__________________
The apostrophe troll.
Reply With Quote
Are inspection referrals from past clients important to you?
If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Exterior Installation of Fire Sprinkler Heads Nick Ostrowski Environmental, Pests, Health and Safety: Home Inspection and Commercial Inspection 10 01-12-2008 06:56 PM
Globe Fire Sprinkler Corp. Thom Walker Safety Recalls and Notices 0 06-12-2007 03:39 PM


All times are GMT -7. The time now is 01:30 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger