You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!

If you have any problems with the registration process or your account login, please contact us.

Why join InspectionNews? Read the Testimonials
Reply
 
LinkBack Thread Tools Search this Thread
  #1 (permalink)  
Old 06-06-2008, 08:57 PM
Seth Hughes
 
Posts: n/a
Water Heater
Any input on this water heater from these pics?
Attached Images
File Type: jpg 100_1374.jpg (43.5 KB, 97 views)
File Type: jpg 100_1384.jpg (40.2 KB, 88 views)
File Type: jpg 100_1388.jpg (46.8 KB, 94 views)
File Type: jpg 100_1391.jpg (46.6 KB, 95 views)
Reply With Quote
Home inspection
  #2 (permalink)  
Old 06-06-2008, 11:13 PM
fritzkelly fritzkelly is online now
Member
 
Join Date: Mar 2007
Location: Camp Verde, Arizona
Posts: 464
Re: Water Heater
Shut off valve is leaking. The vent is not fastened at the draft hood and joints. Jerry will complain about the corrugated flex drain line on the TPR. Pretty typical installation.
Reply With Quote
  #3 (permalink)  
Old 06-07-2008, 06:57 AM
Joshua Hardesty Joshua Hardesty is offline
Member
 
Join Date: Mar 2007
Posts: 118
Re: Water Heater
I'd complain more about the unsupported quest on the other side of that flexi connector on the TPR. 8|
Reply With Quote
  #4 (permalink)  
Old 06-07-2008, 09:51 AM
Jerry McCarthy's Avatar
Jerry McCarthy Jerry McCarthy is offline
Member
 
Join Date: Mar 2007
Location: San Mateo, CA
Posts: 1,114
Re: Water Heater
I don't know which Jerry you mean, but I'll bet both of them agree the PTRV piping is wrong. Also, is that WH located within an attic? If so, where's the drain-pan? And where's the electrical bonding jumper? And I don't see any connector screws in the flue vent piping? And if that WH is located anywhere in CA where's the seismic strapping? (and I'll bet EC Jerry finds additional stuff)
__________________
Jerry McCarthy
Construction Consultant
www.expertbuildingconsultants.com
Reply With Quote
  #5 (permalink)  
Old 06-07-2008, 11:39 AM
Dom D'Agostino Dom D'Agostino is offline
Member
 
Join Date: Mar 2007
Location: Longwood, FL
Posts: 307
Re: Water Heater
Quote:
Originally Posted by Jerry McCarthy View Post
Also, is that WH located within an attic? If so, where's the drain-pan?

Right under the unit. You can see it in the photos. It looks like a formed sheet metal pan.

Quote:
Originally Posted by Jerry McCarthy View Post
And where's the electrical bonding jumper?

The piping is plastic. Again, refer to the photos.

Seth,

If you specific questions, feel free to ask them. Asking for input is holding a door wide open for all kinds of submissions.

Dom.
Reply With Quote
  #6 (permalink)  
Old 06-07-2008, 01:13 PM
Jerry McCarthy's Avatar
Jerry McCarthy Jerry McCarthy is offline
Member
 
Join Date: Mar 2007
Location: San Mateo, CA
Posts: 1,114
Re: Water Heater
Dom & Seth, I lightened up a couple of photos and other than the PTRV piping connected to the corrugated copper I don't see any plastic piping? I now see the pan and even a sediment trap for the gas supply piping. BTW, Adobe Elements #6 is a great tool for a fixen photos.
Attached Images
File Type: jpg WH-30-1.jpg (147.7 KB, 33 views)
File Type: jpg WH-31-a.jpg (121.0 KB, 38 views)
__________________
Jerry McCarthy
Construction Consultant
www.expertbuildingconsultants.com
Reply With Quote
  #7 (permalink)  
Old 06-07-2008, 01:47 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 1,292
Re: Water Heater
Does an attic constitute the home as far as copper pipe for the gas line?
Reply With Quote
  #8 (permalink)  
Old 06-07-2008, 02:13 PM
Dom D'Agostino Dom D'Agostino is offline
Member
 
Join Date: Mar 2007
Location: Longwood, FL
Posts: 307
Re: Water Heater
Jerry,

Look at the 4th photo. Under the insulation you can see the poly crimp to the copper flex connector.

Dom.
Reply With Quote
  #9 (permalink)  
Old 06-07-2008, 02:44 PM
Ted Menelly Ted Menelly is offline
Member
 
Join Date: Mar 2007
Location: Fort Worth, Texas
Posts: 1,292
Re: Water Heater
G2413.5 (403.5) Metallic tubing. Seamless copper,aluminum,or streel tubing shall be permitted to be used with gasses not corrosive to such material.

G2413.5.2 (403.5.2)Copper tubing shall comply with standard Type K or L of ASTM B88 or ASTM B280.

Copper and brass tubing shall not be used if the gas contains more than an average of 0.3 grains of hydrogen sulfide per 100 standard cubic feet of gas.


Unless I can verify all that (unless I am reading in all the wrong areas) I write up copper pipe being used anywhere inside a home (basement, living area, attic) . Every time I have, a plumber changed it out.

Please anyone add input because this is what I was told and or read or tested on for years. I would like to know your opinions. The substance put into natural gas is sulfides so yo can smell it unless I am reading it wrong as well. Like I said I would like advise on this subject.

Ted

I am very rusty on codes. That is one reason I came to this site and also started reading the books again. Slacking off I guess. Need to brush up. A lot!!!!!

Last edited by Ted Menelly : 06-07-2008 at 04:12 PM.
Reply With Quote
  #10 (permalink)  
Old 06-07-2008, 05:08 PM
Jerry McCarthy's Avatar
Jerry McCarthy Jerry McCarthy is offline
Member
 
Join Date: Mar 2007
Location: San Mateo, CA
Posts: 1,114
Re: Water Heater
Dom
Thanks for pointing that detail out, old eyes (mine) sometimes miss vital details. Here's a decent web-site regarding Pex piping installations. http://www.healthyarkansas.com/phc/p...egulations.htm
__________________
Jerry McCarthy
Construction Consultant
www.expertbuildingconsultants.com
Reply With Quote
  #11 (permalink)  
Old 06-07-2008, 07:56 PM
Jerry Peck Jerry Peck is offline
Member
 
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,732
Re: Water Heater
What I see at first glance, starting with the first photo and progressing to the last photo, is:

- T&P flex copper is unsupported
- T&P flex copper connects to PB for T&P discharge line - PB is not approved for use as T&P discharge line material
- T&P PB discharge line goes uphill
- no sediment trap on gas line
- gas line bend, and weigh of gas line, could cause a kink with the gas line coming vertically up off the gas valve like that
- what's that scorch mark above the gas valve
- water heater setting in drain pan, which is intended to catch water in it, which will cause the water heater to rust out
- B vent is not secured to draft hood
- draft hood is not secured to top of water heater
__________________
Jerry Peck, Construction / Litigation Consultant
Construction Litigation Consultants, LLC ( www.ConstructionLitigationConsultants.com )
Reply With Quote
Are inspection referrals from past clients important to you? If so, click here to get even more referrals!
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
gas water heater Jerome W. Young Fireplaces, Chimneys and Solid Fuel Burning Appliances: Home Inspection and Commercial Inspection 25 07-19-2008 11:12 AM
Tankless water heater Rick Maday Plumbing System: Home Inspection and Commercial Inspection 11 04-08-2008 02:39 PM
Hot Water Heater Tom Rees Plumbing System: Home Inspection and Commercial Inspection 3 04-02-2008 09:35 PM
Water Heater Jeff Eastman Plumbing System: Home Inspection and Commercial Inspection 5 07-23-2007 06:31 PM
Who's Water Heater is This Shane Pouch Plumbing System: Home Inspection and Commercial Inspection 3 05-11-2007 08:06 PM


All times are GMT -7. The time now is 03:30 PM.


Design by Vjacheslav Trushkin.
Powered by vBulletin® Version 3.6.5
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0 RC8
vB.Sponsors
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by RedTyger