You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

05-05-2007, 01:15 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Connecticut
Posts: 798
|
|
|
New one to me
Anyone seen one of these before? I haven't.
|
|

05-05-2007, 01:32 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Longwood, FL
Posts: 299
|
|
|
Re: New one to me
I guessing they use it to drain the water line for the Winter without using a bucket?
Dom.
|
|

05-05-2007, 01:58 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Connecticut
Posts: 798
|
|
|
Re: New one to me
I like that one. MAkes sense. Any other ideas out there?
|
|

05-05-2007, 02:48 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Myrtle Beach, South Carolina
Posts: 295
|
|
|
Re: New one to me
Was there a trap just below?
|
|

05-05-2007, 02:48 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Aloha Oregon
Posts: 125
|
|
|
Re: New one to me
If thats the case wouldn't you need a back flow valve on the line.
|
|

05-05-2007, 02:56 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Connecticut
Posts: 798
|
|
|
Re: New one to me
No, No trap below.
|
|

05-05-2007, 08:06 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,041
|
|
|
Re: New one to me
Major, major cross connection.
Great potential for contamination of the potable water supply.
|
|

05-05-2007, 08:09 PM
|
|
Member
|
|
Join Date: May 2007
Location: NC
Posts: 470
|
|
|
Re: New one to me
What are the two 3/4' pipes feeding above?
|
|

05-05-2007, 08:11 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 582
|
|
|
Re: New one to me
The cross contamination was what I picked up on. But I do have a question about it. That looks like a disconnect at the potable source. If the two were connected only during the time of draining the lines and if the bib had a backflow prevention device on it, would it still be a cross contamination circumstance?
__________________
The only reason some people get lost in thought is because it's unfamiliar territory.
- Paul Fix
|
|

05-05-2007, 08:17 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,041
|
|
|
Re: New one to me
Thom,
I my opinion, yes.
The blue (PEX?) line from the DWV WILL BE contaminated *all the time* from bacteria entering from the waste connection.
That puts the contaminated water right up there at the hose bibb.
If you look closely, you will see two hose bibbs and one line, which means that that 'draining line' is to be moved from hose bibb to hose bibb, you know, so they can make sure they contaminate BOTH potable water lines.
I don't see any backflow preventer either.
For something like that, you would need a major multiple purpose backflow preventer - did you go to the Watts site and order those DVDs? If so, watch the one of Backflow Prevention, if not order them and then watch it.
|
|

05-05-2007, 08:27 PM
|
|
Member
|
|
Join Date: May 2007
Location: NC
Posts: 470
|
|
|
Re: New one to me
An indirect waste connection may be another option...like on a reverse osmosis system. No backflow device needed as long as there is an air gap..
|
|

05-05-2007, 08:35 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,041
|
|
|
Re: New one to me
Originally Posted by James Duffin
No backflow device needed as long as there is an air gap..
Which in and of itself is a backflow prevention device. But not all cross connections are allowed to use air gaps as air gaps are not always reliable for the prevention of a cross connection.
Contamination can cross the air gap, spillage, splashing, evaporation, a number of different reasons, including backpressure (in this case, an air gap could overflow if the DWV line clogged and backed up).
|
|

05-05-2007, 08:48 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 582
|
|
|
Re: New one to me
They are ordered now.
As I said, I would have called out the cross contamination risk. I just wondered if there was a way to use the idea without cross contaminating.
__________________
The only reason some people get lost in thought is because it's unfamiliar territory.
- Paul Fix
|
|

05-05-2007, 08:54 PM
|
|
Member
|
|
Join Date: May 2007
Location: NC
Posts: 470
|
|
|
Re: New one to me
This simple 1/4" darin hose could dump into an air gap without a RPZ device I believe. Please share with us your acceptable connection.
|
|

05-14-2007, 10:39 PM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 582
|
|
|
Re: New one to me
Originally Posted by Jerry Peck
For something like that, you would need a major multiple purpose backflow preventer - did you go to the Watts site and order those DVDs? If so, watch the one of Backflow Prevention, if not order them and then watch it.
I got them last night and watched them tonight. The one on scalding should be watched by everyone on the planet.
__________________
The only reason some people get lost in thought is because it's unfamiliar territory.
- Paul Fix
|
|

05-15-2007, 07:51 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Santa Rosa, CA
Posts: 635
|
|
|
Re: New one to me
Jerry,
I must have missed the post about the Watts DVD. I went to their site and was unable to find the link. Can you help?
Thanks
__________________
What is the circumference of a moose?
|
|

05-15-2007, 07:56 AM
|
 |
Member
|
|
Join Date: Mar 2007
Location: Corpus Christi, TX
Posts: 582
|
|
|
Re: New one to me
__________________
The only reason some people get lost in thought is because it's unfamiliar territory.
- Paul Fix
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
All times are GMT -7. The time now is 02:08 PM.
| | |
|