You are currently viewing InspectionNews as a guest which gives you limited access to view most discussions but not pictures. There are over 6,300 inspectors who have already joined. By joining InspectionNews you will be able to see the pictures, have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features. Registration is fast and simple so please, join InspectionNews today!
If you have any problems with the registration process or your account login, please contact us.
Why join InspectionNews? Read the Testimonials
|
|

08-07-2008, 08:32 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Washington State
Posts: 95
|
|
|
Protective vehicle stop (bollards) in garage
I inspected a 2005 built home today with a gas water heater located in garage. No vehicle protection or (bollards) were installed in front of the gas water heater. The water heater sits off to the front corner and is not in direct path with an incoming vehicle that is if your coming in straight. I am thinking that protection is still needed. What is the code or standard for vehicle protection.
|
|

08-07-2008, 08:50 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,417
|
|
|
Re: Protective vehicle stop (bollards) in garage
Trent,
I've never seen bollard protection as of yet and will probably have a stroke the first time I see them.
IRC code {1307.3.1} states, In garage-protect from damage by vehicles
rick
|
|

08-07-2008, 08:51 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,732
|
|
|
Re: Protective vehicle stop (bollards) in garage
Originally Posted by Trent Tarter
I am thinking that protection is still needed. What is the code or standard for vehicle protection.
That it is required.
P2801.2 Installation. Water heaters shall be installed in accordance with this chapter and Chapters 20 and 24.
G2408.3 (305.5) Private garages.Appliances located in private garages shall be installed with a minimum clearance of 6 feet (1829 mm) above the floor.
- Exception: The requirements of this section shall not apply where the appliances are protected from motor vehicle impact and installed in accordance with Section G2408.2.
M1307.3.1 Protection from impact. Appliances located in a garage or carport shall be protected from impact by automobiles.
|
|

08-07-2008, 08:54 PM
|
|
Member
|
|
Join Date: Mar 2007
Location: Ormond Beach, Florida
Posts: 7,732
|
|
|
Re: Protective vehicle stop (bollards) in garage
Originally Posted by Rick Hurst
I've never seen bollard protection as of yet and will probably have a stroke the first time I see them.
At which time you will stop writing them up ... right? 
|
|

08-07-2008, 09:01 PM
|
 |
Member
|
|
Join Date: Oct 2003
Location: Rockwall Texas
Posts: 2,417
|
|
|
Re: Protective vehicle stop (bollards) in garage
Only if they can pull the pen from my dead hand. Didn't Heston say something like that?
rick
__________________
Rick Hurst_Home Works Inspection Co_Rockwall TX
In the words of Mike Tyson.... "Everyone has a plan until they get hit inda mouf"
|
|

08-07-2008, 09:05 PM
|
 |
Member
|
|
Join Date: Aug 2007
Location: Memphis TN.
Posts: 1,623
|
|
|
Re: Protective vehicle stop (bollards) in garage
Originally Posted by Rick Hurst
IRC code {1307.3.1} states, In garage-protect from damage by vehicles
rick
.
Rick,
And what do you think all those Xmas Decorations, like New Sports Equipment & assorted ? Collectibles ! ( function is if not to protect the WH ?) 
__________________
It Might have Choked Artie But it ain't gone'a choke Stymie!
Billy J. Stephens HI Service
Memphis TN.
|
|
| Thread Tools |
Search this Thread |
|
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
| Thread |
Thread Starter |
Forum |
Replies |
Last Post |
| Garage gap |
Ryan Stouffer |
H E L P ! |
8 |
05-28-2008 10:33 AM |
| TX vehicle tax |
John Brown |
Business Operations: Home Inspectors & Commercial Inspectors |
16 |
03-12-2008 11:03 AM |
| Water heater - vehicle impact |
Jeff Eastman |
Plumbing System: Home Inspection and Commercial Inspection |
12 |
07-30-2007 01:11 PM |
| Insulation over garage |
M Kelekci |
Attic Areas: Home Inspection and Commercial Inspection |
14 |
07-23-2007 07:46 PM |
| Moisture stop, brick ledge |
John Stephenson |
Building Envelope: Home Inspection and Commercial Inspection |
1 |
06-05-2007 04:08 PM |
All times are GMT -7. The time now is 02:22 PM.
| | |
|
All Rights Reserved. Hann Tech Marketing Link / InspectionNews.com / InspectionNews.net - No part of InspectionNews.net may be reproduced in any way, or by any means, without the prior written permission of InspectionNews.net. Use of any index or listing Software for the purpose of constructing a mailing list, creating promotional materials or producing a printed or electronic catalog of any kind is expressly forbidden without the prior written permission of InspectionNews.net - All text, graphics and design on InspectionNews.net is copyright by Hann Tech Marketing Links.
Ad Management by
RedTyger